Brand Name
BTU Input
BTU Output
Voltage
AFUE
Configuration
Stages
Communicating
Motor Type
CFM
Width
|◀ 265 - 276 of 286 ▶|
View:
  • Flame roll-out sensors standard
  • Category I venting
  • Blocked vent switch
  • Louvered door
  • 24 VAC and 115 VAC humidifier terminal
  • Electronic air cleaner terminal
  • Adjustable heating blower OFF delay
  • Factory set blower ON delay
  • High temperature limit control prevents overheating
  • 1-piece pre-painted steel cabinet
  • Quieter in-shot burners
  • Innovative knobs for easy door removal and secure attachment
  • 4-position - Upflow/downflow/horizontal (left/right) installation
  • 3-position inducer elbow capability
  • Through the casing flue pipe for counterflow applications



    International Comfort Products R80MSL0701716A

  • Item#:
    R80MSL0902120A
    Manufacturer Item:
    R80MSL0902120A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Up to 92.1% AFUE in upflow, horizontal and downflow positions
  • Single-stage gas valve
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for manufactured housing/mobile home applications with accessory (order separately)
  • Select sizes approved for twinning, refer to accessory kit listing
  • All sizes can be installed in air quality management districts with a 40 ng/NOx emissions requirement



    International Comfort Products R92MSN0801716A

  • Item#:
    R92MSN1002120A
    Manufacturer Item:
    R92MSN1002120A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Flame roll-out sensors standard
  • Category I venting
  • Blocked vent switch
  • Louvered door
  • 24 VAC and 115 VAC humidifier terminal
  • Electronic air cleaner terminal
  • Adjustable heating blower OFF delay
  • Factory set blower ON delay
  • High temperature limit control prevents overheating
  • 1-piece pre-painted steel cabinet
  • Quieter in-shot burners
  • Innovative knobs for easy door removal and secure attachment
  • 4-position - Upflow/downflow/horizontal (left/right) installation
  • 3-position inducer elbow capability
  • Through the casing flue pipe for counterflow applications



    International Comfort Products N96VSN1002120B

  • Item#:
    R80MSL0451412A
    Manufacturer Item:
    R80MSL0451412A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Up to 92.1% AFUE in upflow, horizontal and downflow positions
  • Single-stage gas valve
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for manufactured housing/mobile home applications with accessory (order separately)
  • Select sizes approved for twinning, refer to accessory kit listing
  • All sizes can be installed in air quality management districts with a 40 ng/NOx emissions requirement



    International Comfort Products R92ESN0801716A

  • Item#:
    R92MSN0401412A
    Manufacturer Item:
    R92MSN0401412A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Up to 92.1% AFUE in upflow, horizontal and downflow positions
  • Single-stage gas valve
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for manufactured housing/mobile home applications with accessory (order separately)
  • Select sizes approved for twinning, refer to accessory kit listing
  • All sizes can be installed in air quality management districts with a 40 ng/NOx emissions requirement



    International Comfort Products R92MSN0401412A

  • Item#:
    R92MSN0601714A
    Manufacturer Item:
    R92MSN0601714A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Up to 92.1% AFUE in upflow, horizontal, and downflow positions
  • Single-stage gas valve and fixed-speeds, constant torque ECM.
  • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193
  • Approved for Manufactured Housing/Mobile Home applications with accessory (order separately)
  • NOx emissions less than 40 ng/J; can be installed in California air quality management districts with a 40 ng/J NOx emission limit.
  • Flame roll-out sensors standard
  • Adjustable heating blower OFF delay
  • Factory set blower ON delay
  • RPJ primary heat exchanger
  • Stainless steel secondary heat exchanger
  • High temperature limit control designed to prevent overheating
  • Direct ignition with Silicon Nitride ignitor
  • High quality, corrosion-resistant, prepainted steel cabinet



    International Comfort Products R80MSU0802120A

  • Item#:
    R92ESN0801716A
    Manufacturer Item:
    R92ESN0801716A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Flame roll-out sensors standard
  • Category I venting
  • Blocked vent switch
  • Louvered door
  • 24 VAC and 115 VAC humidifier terminal
  • Electronic air cleaner terminal
  • Adjustable heating blower OFF delay
  • Factory set blower ON delay
  • High temperature limit control prevents overheating
  • 1-piece pre-painted steel cabinet
  • Quieter in-shot burners
  • Innovative knobs for easy door removal and secure attachment
  • 4-position - Upflow/downflow/horizontal (left/right) installation
  • 3-position inducer elbow capability
  • Through the casing flue pipe for counterflow applications



    International Comfort Products R80MSL0701412A

  • Item#:
    R80MSL0701716A
    Manufacturer Item:
    R80MSL0701716A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Up to 97% AFUE in upflow/horizontal, up to 95% AFUE in downflow
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Supports single-stage cooling units
  • Insulated heat exchanger compartment
  • All sizes can be installed in air quality management districts with a 40 ng/J NOx emissions requirement
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for twinning applications (0601716, 0801716, 0802120, 1002120, 1202422) with accessory (order separately)
  • Approved for manufactured housing/mobile home applications (0401410 through 1202422) with accessory (order separately)



    International Comfort Products R96MSN0401410A

  • Item#:
    R96MSN0401712A
    Manufacturer Item:
    R96MSN0401712A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Multi 18-Speed, Constant Torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • 80% AFUE
  • Flame rollout sensors standard
  • Category I venting
  • Blocked vent switch
  • Louvered door
  • 24 VAC humidifier terminal
  • Electronic air cleaner terminal
  • Select sizes approved for twinning, refer to accessory kit listing
  • R80MSL - Low NOx units are designed for California installations and can be installed in air quality management districts with a 40ng/J NOx emissions limit
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193



    International Comfort Products R80MSL1102120A

  • Item#:
    R80MSN0701412A
    Manufacturer Item:
    R80MSN0701412A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York Z9ET060B12SMPS1

  • Item#:
    Z9ET080B12SMPS1
    Manufacturer Item:
    Z9ET080B12SMPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York Z9ET080C16SMPS1

  • Item#:
    Z9ET100C16SMPS1
    Manufacturer Item:
    Z9ET100C16SMPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME
    Features
  • Easily applied in upflow, horizontal left or horizontal right, or downflow installation with minimal conversion necessary.
  • Venting kit for downflow (counter-flow) applications on B, C, and D cabinets where side discharge is not possible.
  • The unit cabinet is compact and easy to install with an ideal height of 33 in.
  • Full length fold-up duct connector flanges for application flexibility.
  • Easy access to controls to connect power and control wiring.
  • No electrical knockouts to deal with, making installation easier.
  • 24 V, 40 VA control transformer and control provisions supplied for single or multi-stage add on cooling or heat pump heating.
  • Built-in, high level self diagnostics with fault code displays standard on integrated control module for reliable operation.
  • Front-facing screws on flame sensor and hot surface ignitor for ease of service.
  • Front-facing screws on blower assembly for easy access and removal of blower.
  • Constant torque blower motor for cooling SEER2 enhancement.
  • Blower-off delay for cooling SEER2 improvement.
  • Continuous fan options for indoor air quality (IAQ) performance.
  • Airflow leakage less than 2% of nominal airflow for duct performance testing conditions.
  • Low unit current requirement for easy replacement application.
  • Electronic hot surface ignition saves fuel cost with increased dependability and reliability.
  • 100% shut-off main gas valve for extra safety.
  • Inducer rotates for easy conversion of venting options.
  • Five-speed direct drive standard ECM blower motor.
  • Hi-tech tubular aluminized steel primary heat exchanger.
  • Corrosion resistant stainless steel secondary heat exchanger including rear cover pan and front vestibule panel.
  • Quiet inducer operation.
  • Timed on, adjustable off blower capability for maximum comfort.
  • Blower door safety switch below the blower deck.
  • Solid removable bottom panel allows easy conversion for bottom return air applications.
  • External air filters are used for maximum flexibility in meeting customers' IAQ needs.
  • 1/4 turn knobs are provided for easy independent door removal.
  • Insulated blower compartment for thermal and acoustic performance.
  • Internal condensate trap design (patent pending) provides condensate management options and is self priming to prevent nuisance problems.
  • Protection included from air intake, exhaust vent, or condensate blockage. Venting applications may be installed as either two-pipe sealed combustion or single-pipe vent using indoor combustion air.
  • No special vent termination required.
  • These condensing furnace models produce <40 ng/J NOx emissions.
  • Fold-up duct connector flanges for application flexibility.
  • Patented self-priming internal condensate trap design for easy installation.

    York Z9ET040A10SMPS1

  • Item#:
    Z9ET060B12SMPS1
    Manufacturer Item:
    Z9ET060B12SMPS1
    Manufacturer:
    JC RESIDENTIAL AND LIGHT COMME