Air conditioning, heat pump, truck refrigeration and many other applications require intermittent operation of the refrigeration compressor. Especially in remote applications, the suction line may trap or hold quantities of liquid which are suddenly dumped into the compressor as it starts up. This is frequently the cause of broken valves, pisTons, broken or bent connecting rods, blown gaskets and bearing washout. Proper installation of the Refrigeration Research suction accumulator in the suction line, just before the compressor, eliminates damage. If correctly sized, relatively large quantities of liquid refrigerant may return through the suction line and the suction accumulator prevents damage to the compressor. Liquid is temporarily held in the suction accumulator and metered back to the compressor along with any oil, at a controlled rate, through the metering orifice. Therefore, damage to the compressor is prevented and the compressor immediately and quietly goes to work.
    ,

    Refrigeration Research 3700-01

    ,

    3700-01

    Item#:
    3700-01
    Manufacturer Item:
    3700-01
    Manufacturer:
    REFRIGERATION RESEARCH INC
    Refrigeration Research 3817 Suction Accumulator 1/2" Vertical,

    3817

    ,

    3817

    Item#:
    3817
    Manufacturer Item:
    3817
    Manufacturer:
    REFRIGERATION RESEARCH INC
    Refrigeration Research 3706 Suction Accumulator 1-3/8" Vertical,

    3706

    ,

    3706

    Item#:
    3706
    Manufacturer Item:
    3706
    Manufacturer:
    REFRIGERATION RESEARCH INC
    Refrigeration Research 3703 Suction Accumulator 3/4" Vertical,

    3703

    ,

    3703

    Item#:
    3703
    Manufacturer Item:
    3703
    Manufacturer:
    REFRIGERATION RESEARCH INC
    White Rodgers Cooling Controls Cooling Controls A-AS 3 84 Suction Accumulator 3" x 8"

    The A-AS protects the compressor from liquid slugging and is used with CFC, HCFC and HFC refrigerants. It is available for systems through 28 tons nominal capacity.

  • Designed to operate in a range of +40°F to -40°F evaporator temperature
  • Fusible plug on larger diameter units
  • Solid copper connections
  • Corrosion resistant epoxy powder paint finish
  • Inlet deflector directs refrigerant flow to prevent internal splashing and aid in the collection of refrigerant oil,

    A-AS 3 84

  • Item#:
    A-AS 3 84
    Manufacturer Item:
    060819
    Manufacturer:
    WHITE-RODGERS COOLING CONTROLS
    Refrigeration Research 3702 Suction Accumulator 5/8" Vertical,

    3702

    ,

    3702

    Item#:
    3702
    Manufacturer Item:
    3702
    Manufacturer:
    REFRIGERATION RESEARCH INC
    White Rodgers Cooling Controls A-AS 5 139 Suction Accumulator 5" x 12"

    The A-AS protects the compressor from liquid slugging and is used with CFC, HCFC and HFC refrigerants. It is available for systems through 28 tons nominal capacity.

  • Designed to operate in a range of +40°F to -40°F evaporator temperature
  • Fusible plug on larger diameter units
  • Solid copper connections
  • Corrosion resistant epoxy powder paint finish
  • Inlet deflector directs refrigerant flow to prevent internal splashing and aid in the collection of refrigerant oil,

    A-AS 5 139

  • Item#:
    A-AS 5 139
    Manufacturer Item:
    060815
    Manufacturer:
    WHITE-RODGERS COOLING CONTROLS
    White Rodgers Cooling Controls A-AS 5 97 Suction Accumulator 5" x 9"

    The A-AS protects the compressor from liquid slugging and is used with CFC, HCFC and HFC refrigerants. It is available for systems through 28 tons nominal capacity.

  • Designed to operate in a range of +40°F to -40°F evaporator temperature
  • Fusible plug on larger diameter units
  • Solid copper connections
  • Corrosion resistant epoxy powder paint finish
  • Inlet deflector directs refrigerant flow to prevent internal splashing and aid in the collection of refrigerant oil,

    A-AS 5 97

  • Item#:
    A-AS 5 97
    Manufacturer Item:
    060818
    Manufacturer:
    WHITE-RODGERS COOLING CONTROLS
    White Rodgers Cooling Controls A-AS 6 1411 Suction Accumulator 1-3/8", 6" x 14"

    The A-AS protects the compressor from liquid slugging and is used with CFC, HCFC and HFC refrigerants. It is available for systems through 28 tons nominal capacity.

  • Designed to operate in a range of +40°F to -40°F evaporator temperature
  • Fusible plug on larger diameter units
  • Solid copper connections
  • Corrosion resistant epoxy powder paint finish
  • Inlet deflector directs refrigerant flow to prevent internal splashing and aid in the collection of refrigerant oil,

    A-AS 6 1411

  • Item#:
    A-AS 6 1411
    Manufacturer Item:
    060827
    Manufacturer:
    WHITE-RODGERS COOLING CONTROLS
    Item#:
    HX3738
    Refrigeration Research 3738 Suction Accumulator 7/8" Vertical,

    Refrigeration Research 3738

    ,

    3738

    Item#:
    3738
    Manufacturer Item:
    3738
    Manufacturer:
    REFRIGERATION RESEARCH INC
    Copeland 577-0286-01 Suction Accumulator, 7/8 x 1-1/4" Sweat x Rotalock

  • Make sure you ask for and use genuine Copleand parts. Copeland parts fit right, first time. Insisting on genuine Copeland parts will keep your refrigeration & A/C Conpressor running reliably for the low haul. ,

    577-0286-01

    ,

    577-0286-01

  • Item#:
    577-0286-01
    Manufacturer Item:
    577-0286-01
    Manufacturer:
    COPELAND LP
    |◀ 13 - 24 of 24 ▶|