S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F
,
,
Sid Harvey Remanufactured C293-3R
Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D
- Pressure actuated high limit, safety control for steam heating boilers, It breaks an electrical circuit to shut down the burner if steam pressure rises above a safe level
- Contains an SPST Micro switch snap-acting switch
- Sensitive pressure actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
- A screw on top of the case allows setpoint adjustment without removing the cover
- Differential is adjusted by means of a dial located inside the case
- Recommended minimum setpoint is differential setting plus 1-1/2 psi
- Stainless steel diaphragm sensor element
- Makes at setpoint on pressure fall breaks at setpoint plus differential on pressure rise Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D,
Sid Harvey Remanufactured C354-1R
Item#:
C354R
Manufacturer Item:
PA404A1033
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,
,
,
Sid Harvey Remanufactured C290R
Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
,
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
,
Sid Harvey Remanufactured C317-14R
Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,
,
,
Sid Harvey Remanufactured C354R
Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
- ,
,
Sid Harvey Remanufactured C434-7R
Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-7R Fan limit Control 5'' REMANUFACTURED,
,
,
Sid Harvey Remanufactured C434-12R
Item#:
C434-7R
Manufacturer Item:
C434-7R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey B163-114R Replacement Valve Stem Assembly for 3/4",
,
,
Sid Harvey Remanufactured B163-113R
Item#:
B163-114R
Manufacturer Item:
F84-0433
Manufacturer:
SID HARVEY REMANUFACTURED