Sid Harvey C312-10R High Limit Aquastat Relay, 100 - 240 deg F
Sid Harvey Item #:C312-10R: Replaces Part #:'s : 0R258,
,



Sid Harvey Remanufactured C293-3R

Item#:
C312-10R
Manufacturer Item:
C312-10
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D
  • Pressure actuated high limit, safety control for steam heating boilers, It breaks an electrical circuit to shut down the burner if steam pressure rises above a safe level
  • Contains an SPST Micro switch snap-acting switch
  • Sensitive pressure actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
  • A screw on top of the case allows setpoint adjustment without removing the cover
  • Differential is adjusted by means of a dial located inside the case
  • Recommended minimum setpoint is differential setting plus 1-1/2 psi
  • Stainless steel diaphragm sensor element
  • Makes at setpoint on pressure fall breaks at setpoint plus differential on pressure rise Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D,



    Sid Harvey Remanufactured C354-1R

Item#:
C354R
Manufacturer Item:
PA404A1033
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,
,



Sid Harvey Remanufactured C290R

Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Sid Harvey Item #:C317-2R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317R,
,



Sid Harvey Remanufactured C317-14R

Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,
,



Sid Harvey Remanufactured C354R

Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C434-9R Fan Limit Control, Remanufactured
  • ,
    ,



    Sid Harvey Remanufactured C434-7R

Item#:
C434-9R
Manufacturer Item:
C434-9
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-7R Fan limit Control 5'' REMANUFACTURED,
,



Sid Harvey Remanufactured C434-12R

Item#:
C434-7R
Manufacturer Item:
C434-7R
Manufacturer:
SID HARVEY REMANUFACTURED
Item#:
A28-69R
Item#:
B163-80R
Sid Harvey B163-114R Replacement Valve Stem Assembly for 3/4",
,



Sid Harvey Remanufactured B163-113R

Item#:
B163-114R
Manufacturer Item:
F84-0433
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 85 - 96 of 175 ▶|