|◀ 85 - 96 of 202 ▶|
View:
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L8151A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service.
    Provides high limit, low limit and circulator control for maintaining boiler temperatures
  • Can provide multizone control by using a separate thermostat and R845 Relay for each zone
  • An internal transformer powers the thermostat circuit
  • Shielded capillary allows convenient mounting
  • Consists of a diaphragm powerhead and micro switch assembly that responds to temperature changes in the boiler water
  • Mounting lugs on back of case
Item#:
C317-13R
Manufacturer Item:
L8151A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C317R Triple Aquastat, 110 - 220 deg F Low Limit, 130 - 240 deg F High Limit, 10 - 25 deg F Adjustable Low Limit, 10 deg F Fixed High Limit Differential, SPST, 120 VAC, Remanufactured
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water
  • Provides multi zone control by using a separate circulator and relay for each zone
  • Includes diaphragm power head and Micro-Switch assembly that respond to temperature changes in boiler water
  • Mounts directly to boiler
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 ampSid Harvey Item #:C317R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317-2R,
Item#:
C317R
Manufacturer Item:
L8024A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L7224U oil electronic aquastat controller provides electronic temperature sensing in a UL limit-rated controller, controls the circulator, oil burner and boiler temperature, and provides status, LED diagnostic and EnviroCOM communication.
  • EnviraCOM, a low-cost 3-wire communication protocol that allows different devices, such as communicating thermostats, aquastats and oil primaries, to connect and share information Honeywell L7224U1002 Electronic Oil Aquastat, 120 VAC, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit , 5 - 20 deg F Fixed High Limit, 10 - 25 deg F Adjustable Low Limit Differential
Item#:
C317-14R
Manufacturer Item:
L7224U1002
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
    Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor

Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-ScaleSid Harvey Item #:C290R: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290A |,
Item#:
C290R
Manufacturer Item:
L4006A1678-2007
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C354-1R Pressuretrol Controller, SPST, 0.5-9 psi Adjustable, 3-3/8" W x 4-15/32" H x 2-1/4" D, Remanufactured
  • The PA404 is a series 40 (2-wire, SPST) pressuretrol controller for use in 24, 120, 240 or 277 volt control circuits or in self powered (millivoltage) applications
  • The PA404B is used with suspension-type unit heaters to make the fan circuit when a pressure rise indicates the presence of steam
  • Each model contains an SPST micro-switch snap-acting switch
  • Sensitive pressure-actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
  • A screw on top of the case allows set point adjustment without removing the cover
  • Differential is adjusted by means of a dial located inside the case
  • Recommended minimum set point is differential setting plus 1-1/2 psi
  • Tradeline value
  • Stainless steel diaphragm sensor element
  • Additive or subtractive differential type
  • Makes at set point plus differential on pressure rise, breaks at set point on pressure fall
  • 50 psi pressure surge
  • 0.5-9 psi adjustable scale range,
Item#:
C354-1R
Manufacturer Item:
PA404B1023
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220
Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,
Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey High Limit Aquastat Relay 8F differential REMANUFACTURED. Immersion type controllers that combine high limit protection with switchingrelay control of burner and circulator motors
    High limit opens burner circuit only.
  • Includes transformer and accessory terminals for adding a remote low limit controller.
  • Case available for horizontal or vertical mounting.
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 amps.
Item#:
C312-8R
Manufacturer Item:
L8148A1017
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 85 - 96 of 202 ▶|
View: