Brand Name
Type
Amperage
Voltage
|◀ 133 - 144 of 189 ▶|
View:
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
  • True dual-element construction allows sizing of 125% FLA for motor backup protection
  • Superior overload and cycling capabilities
  • Provides motor overload, ground fault and short-circuit protection
  • Helps protect motors against burnout from overloads and also from single phasing on three phase systems
  • Current limiting provides component short circuit protection
  • Simplifies and improves blackout prevention
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
  • The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Sid Harvey Item #:E356-45: Replaces Part #:'s : 6551,
,



Bussmann E356-45


Bussmann E356-45

Item#:
E356-45
Manufacturer Item:
ECNR-60
Manufacturer:
COOPER BUSSMAN LLC
The time-delay characteristics of these fuses typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection. These fuses will override normal equipment current surges to reduce unnecessary fuse openings. Have moderate current limitation.
  • True dual-element construction allows sizing of 125% FLA for motor backup protection
  • Superior overload and cycling capabilities
  • Provides motor overload, ground fault and short-circuit protection
  • Helps protect motors against burnout from overloads and also from single phasing on three phase systems
  • Current limiting provides component short circuit protection
  • Simplifies and improves blackout prevention
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
  • The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
,


Bussmann E356-46


Bussmann E356-46

Item#:
E356-46
Manufacturer Item:
ECNR-70
Manufacturer:
COOPER BUSSMAN LLC
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
  • True dual-element construction allows sizing of 125% FLA for motor backup protection
  • Superior overload and cycling capabilities
  • Provides motor overload, ground fault and short-circuit protection
  • Helps protect motors against burnout from overloads and also from single phasing on three phase systems
  • Current limiting provides component short circuit protection
  • Simplifies and improves blackout prevention
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
  • The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds ,
    ,



    Bussmann E356-43


    Bussmann E356-43

Item#:
E356-43
Manufacturer Item:
ECNR-40
Manufacturer:
COOPER BUSSMAN LLC
Diversitech 7-CRNR50 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 50 amp, 250 VAC
  • Provides time delay for temporary over-current conditions and motor running protection
  • Eliminates unnecessary maintenance from harmless overloads
Sid Harvey Item #:E356-44: Replaces Part #:'s : 6550,

,



Bussmann E356-44


Bussmann E356-44

Item#:
E356-44
Manufacturer Item:
ECNR-50
Manufacturer:
COOPER BUSSMAN LLC
Sid Harvey E397-213A Fuse 3 AMP Plastic ATO 5/PK

Sid Harvey E397-213A

Item#:
E397-213A
Manufacturer Item:
E397-213A
Manufacturer:
MITCO MFG.
Sid Harvey E397-415 2-Pole Square D Circuit Breaker 30 amp,
,



E397-415


E397-415

Item#:
E397-415
Manufacturer Item:
E397-415
Manufacturer:
MITCO MFG.
Sid Harvey E397-420 2-Pole Interchangeable Circuit Breaker 15 AMP,
,



Sid Harvey E397-420


Sid Harvey E397-420

Item#:
E397-420
Manufacturer Item:
E397-420
Manufacturer:
MITCO MFG.
Sid Harvey E397-425 2-Pole Interchangeable Circuit Breaker 20 AMP,
,



Sid Harvey E397-425


Sid Harvey E397-425

Item#:
E397-425
Manufacturer Item:
E397-425
Manufacturer:
MITCO MFG.
Sid Harvey E397-440 2-Pole Interchangeable Circuit Breaker 30 AMP,
,



Sid Harvey E397-440


Sid Harvey E397-440

Item#:
E397-440
Manufacturer Item:
E397-440
Manufacturer:
MITCO MFG.
Sid Harvey E397-215 ATO Fuse Assortment
,
,



Sid Harvey E397-215


Sid Harvey E397-215

Item#:
E397-215
Manufacturer Item:
E397-215
Manufacturer:
MITCO MFG.
Fujitsu E397-600 Glass Fuse 3 AMP
Item#:
E397-600
Manufacturer Item:
E397-600
Manufacturer:
MITCO MFG.
Sid Harvey E397-215A ATO Fuse Assortment 100/PK

Sid Harvey E397-215A

Item#:
E397-215A
Manufacturer Item:
E397-215A
Manufacturer:
MITCO MFG.
|◀ 133 - 144 of 189 ▶|