S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor
Parker PSG-2S
Item#:
PSG-2S
Manufacturer Item:
700055-001
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor
PSG-7S
Item#:
PSG-7S
Manufacturer Item:
700509-002
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Sight Glass Moisture Indicator
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor
The Parker PSG Moisture and Liquid Indicator combines the two functions of moisture and liquid indication into a single economical product. It takes the guess work out of servicing refrigeration and air conditioning equipment. The PSG assists the technician in determining the state of the circulating refrigerant at a particular location and if a safe moisture level exists in the system. Excessive moisture in refrigerant systems can cause unwanted chemistries such as hydrolysis of lubricants and other materials, corrosion of metals, copper plating, ice formation at the metering device and a chemical change in the motor insulation of a hermetic compressor
PSG-4MF
Item#:
PSG-4MF
Manufacturer Item:
700262-002
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Repair Kit for R36 series Normally Closed Refrigeration Solenoid Valves
RK3601
Item#:
RK3601
Manufacturer Item:
KS-B10/E10
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker RK3201 Repair Kit For R32 series NC Refrigeration Solenoid Valves
RK3201
Item#:
RK3201
Manufacturer Item:
KS-B9/E9
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Repair Kit For R42 series Normally Closed Refrigeration Solenoid Valves
RK4201
Item#:
RK4201
Manufacturer Item:
KS-B19/E19
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
Parker Solenoid Valve Coil
110/120 VAC
6" lead electrical connection
34 VA inrush, 19 VA holding
Coil insulation class F
Coil enclosure general purpose junction box
Parker RK1P3
The Parker Refrigeration Valves consist of solenoid valves for liquid, suction and hot gas defrost application requirements.
The valves are compatible with virtually all of todays commercially available CFC, HCFC and HFC refrigerants and blends.
The Parker refrigeration valves meet a broad range of system needs including refrigeration, air conditioning and freezing applications.
From small fractional tonnage to large systems. The portfolio is endowed with numerous benefits including
- Normally closed and
normally open valves
- Type: Normally Closed
- Connection 1/4
- Connection: ODF
- Port (In.): 7/64"
- Body Type: Brass
- Safe Working Pressure (PSI): 500
- State of the art operator performance for long life, ease of service and tighter system integrity
- High pressure ratings to comply with R410A
- Extended end sweat connections enable brazing installation without disassembly
- AC & DC coils are interchangeable on all valve body versions
Parker R16E32
Item#:
R16E32
Manufacturer Item:
E3S120-HP
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
The Parker Refrigeration Valves consist of solenoid valves for liquid, suction and hot gas defrost application requirements.
The valves are compatible with virtually all of todays commercially available CFC, HCFC and HFC refrigerants and blends.
The Parker refrigeration valves meet a broad range of system needs including refrigeration, air conditioning and freezing applications.
From small fractional tonnage to large systems. The portfolio is endowed with numerous benefits including
- Normally closed and
normally open valves
- Type: Normally Closed
- Connection 1/4
- Connection: ODF
- Port (In.): 7/64"
- Body Type: Brass
- Safe Working Pressure (PSI): 500
- State of the art operator performance for long life, ease of service and tighter system integrity
- High pressure ratings to comply with R410A
- Extended end sweat connections enable brazing installation without disassembly
- AC & DC coils are interchangeable on all valve body versions
R16E33
Item#:
R16E33
Manufacturer Item:
E3S130-HP
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
The Parker Refrigeration Valves consist of solenoid valves for liquid, suction and hot gas defrost application requirements.
The valves are compatible with virtually all of todays commercially available CFC, HCFC and HFC refrigerants and blends.
The Parker refrigeration valves meet a broad range of system needs including refrigeration, air conditioning and freezing applications.
From small fractional tonnage to large systems. The portfolio is endowed with numerous benefits including
- Normally closed and
normally open valves
- Type: Normally Closed
- Connection 1/4
- Connection: ODF
- Port (In.): 7/64"
- Body Type: Brass
- Safe Working Pressure (PSI): 500
- State of the art operator performance for long life, ease of service and tighter system integrity
- High pressure ratings to comply with R410A
- Extended end sweat connections enable brazing installation without disassembly
- AC & DC coils are interchangeable on all valve body versions
Parker R16F32
Item#:
R16F32
Manufacturer Item:
A3F1
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
The Parker Refrigeration Valves consist of solenoid valves for liquid, suction and hot gas defrost application requirements.
The valves are compatible with virtually all of todays commercially available CFC, HCFC and HFC refrigerants and blends.
The Parker refrigeration valves meet a broad range of system needs including refrigeration, air conditioning and freezing applications.
From small fractional tonnage to large systems. The portfolio is endowed with numerous benefits including
- Normally closed and
normally open valves
- 1/4" OD
- Normally Closed
- R-134A; R-22; R-404A; R-407A; R-407C; R-407F; R-410A; R-448A; R-449A; R-450A; R-507A; R-513A
- State of the art operator performance for long life, ease of service and tighter system integrity
- High pressure ratings to comply with R410A
- Extended end sweat connections enable brazing installation without disassembly
- AC & DC coils are interchangeable on all valve body versions
Parker R12E22
Item#:
R12E22
Manufacturer Item:
E2S120-HP
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)
The Parker Refrigeration Valves consist of solenoid valves for liquid, suction and hot gas defrost application requirements.
The valves are compatible with virtually all of todays commercially available CFC, HCFC and HFC refrigerants and blends.
The Parker refrigeration valves meet a broad range of system needs including refrigeration, air conditioning and freezing applications.
From small fractional tonnage to large systems. The portfolio is endowed with numerous benefits including
- Normally closed and
normally open valves
- Type: Normally Closed
- Connection 1/4
- Connection: ODF
- Port (In.): 7/64"
- Body Type: Brass
- Safe Working Pressure (PSI): 500
- State of the art operator performance for long life, ease of service and tighter system integrity
- High pressure ratings to comply with R410A
- Extended end sweat connections enable brazing installation without disassembly
- AC & DC coils are interchangeable on all valve body versions
Parker R42E195M
Item#:
R42E195M
Manufacturer Item:
ME19S250-HP
Manufacturer:
PARKER HANNIFIN(AFTERMARKET)