S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
White Rodgers Cooling Controls SureSwitch 49P11-843 1.5-Pole Relay, 24 VAC at 50/60 Hz, 40,
49P11-843
Item#:
49P11-843
Manufacturer Item:
49P11-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50A65-843 Universal Nitride Ignition Furnace Control, 25 The 50A55-843 universal silicon carbide integrated ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. This one module will replace most of the 50A5x-xxx integrated ignition carbide modules that have been manufactured by White-Rodgers for most OEM applications. The universal module includes an extensive cross-reference, additional jumper wires, additional wiring harness and a jumper for Trane applications. The module also has terminals for powering a humidifier and electronic air cleaner
Item#:
50A65-843
Manufacturer Item:
50A65-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56U-751 1-Stage HSI Integrated Furnace Control Kit for
Item#:
50M56U-751
Manufacturer Item:
50M56U-751
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50C51-707 2-Stage HSI Integrated Furnace Control 24 VAC
Item#:
50C51-707
Manufacturer Item:
50C51-707
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50N02A-820 DSI Integrated Furnace Control 24 VAC,white rodgers 50n02a-820
Item#:
50N02A-820
Manufacturer Item:
50N02A-820
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50T35-743 Circuit Board
White Rodgers 50T35-743
White Rodgers 50T35-743
Item#:
50T35-743
Manufacturer Item:
B1809913S
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50A56-956 Replacement Integrated Furnace Control, 25 VAC , The 50A56-956 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
Item#:
50A56-956
Manufacturer Item:
50A56-956
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
Application
Single Stage Gas
120v HSI
PSC Blower Motor
Twinning
Standoff Mounting
Replaces 14 SKUs
Features
Red LED Status / Fault Indicator
Fault Recall Button
Heat off delay jumper
2 Park Terminals
Built-in 24v 3A Fuse
1 Hum & EAC Terminal
Item#:
50M56-707
Manufacturer Item:
50M56-707
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A55-843 universal silicon carbide integrated ignition module employs a microprocessor which continually monitors, analyzes and controls the proper operation of the gas burner, inducer and fan. This one module will replace most of the 50A5x-xxx integrated ignition carbide modules that have been manufactured by White-Rodgers for most OEM applications. The universal module includes an extensive cross-reference, additional jumper wires, additional wiring harness and a jumper for Trane applications. The module also has terminals for powering a humidifier and electronic air cleaner.
- Diagnostic LED
- Additional jumpers to extend the length of the connections
Replaces Part #:'s : D330927P01 | D330930P01 | D330934P01 | D340035P01 | D340354P01 | D340774P01 |
Item#:
50A55-843
Manufacturer Item:
50A55-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56U-801Integrated HIS Furnace Control Board
- System diagnostic LED with fault recall
- Fused to protect low voltage system transformers
- 3 fan speeds
- Adapter harness for application flexibility
- 15 sec pre-purge time
- 30/45 heat delay for to fan on, 60/90/120/180 heat delay for to fan off, 2 cool delay for to fan on, 2/60 cool delay for to fan off, default setting
- 5 sec post-purge
- 0.8 sec max flame failure response time
- 2 sec flame failure response time
- 1.5 amp at 25 VAC 50/60 Hz for valve relay, 1.2 amp at 120 VAC 50/60 Hz for ignitor relay
- Surface mount standoffs
- 5 - 93% RH, non-condensing humidity
Item#:
50M56U-801
Manufacturer Item:
50M56U-801
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56U-843 1-Stage HSI Integrated Furnace Control Kit, 25 VAC, 0.45 amp, 5-1/4" W x 7" H x 1-1/4" D
Item#:
50M56U-843
Manufacturer Item:
50M56U-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50A55-743 Replacement Integrated Furnace Control, 25 VAC, 0.45 amp, Import The 50A55-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls.
- Twinning connection
- Fused to protect low voltage system transformers
- 120 VAC igniter output
- 120 VAC humidifier output
- 120 VAC electronic air cleaner output
- 120 VAC 2-speed PSC circulator output
- 5 amp fuse protection
- Furnace status LED
- Heat fan off delay (dipswitch selectable)
- 1.5 amp valve relay
- 6 amp igniter relay
- 2.2 amp full load - 3.5 amp locked rotor inducer relay
- 14.5 amp full load - 25 amp locked rotor circulator relay
- 1 micro-amp DC minimum current
- 0.10 micro-amp DC max current
- 100 mega-ohm leakage resistance
- Maximum timing specification
- 0.8 sec flame establishing
- Flash code diagnostics The 50A55-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls
Item#:
50A55-743
Manufacturer Item:
50A55-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND