Home  > SID HARVEY REMANUFACTURED(x)
|◀ 97 - 108 of 192 ▶|
View:
Sid Harvey Honeywell L8124C High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-5R
Manufacturer Item:
L8124C1003
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Paragon 8000 series commercial defrost controls are designed for commercial freezers and refrigerators to provide automatic defrost capability. They accommodate various types of defrost systems including electric defrost heaters, hot gas, and compressor off cycle.
  • Positive slide bar switch design assures positive electrical contact and wipes the contact surface of contaminates
  • Temperature or pressure terminated models are designed to stop defrosting using an external temperature or pressure device
  • Safety back-up - mechanical time-driven defrost termination
  • Heavy-duty synchronous design drive motor
  • Choice of 3-contact arrangements
  • Adjustable frequency of defrost initiation from 1 - 6-cycles per day with a minimum of 4 hr between successive operations
  • Adjustable back-up defrost termination from 4 - 110 min in 2 min increments
  • Have an adjustable cut-in pressure dial calibrated from 36 - 110 lb for R12, R22, R502
  • Time initiated/temperature or pressure terminated
  • Open switch arrangement for contacts 1 - 3, closed switch arrangement for contacts 2 - 4, closed switch arrangements for contacts 3 - N
  • Electric heat, hot gas or compressor shutdown
  • 1 year limited warranty Paragon 8141-00 Heavy-Duty Steel Commercial Mechanical Defrost Control, 4 - 110 min, SPDT (1) NO - (2) NC, 120 VAC Electrical, 120 - 240 VAC Switch, 40 amp
Item#:
C255-130R
Manufacturer Item:
8141-00
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124L High Limit Triple Aquastat Relay, 24 - 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-11R
Manufacturer Item:
L8124L1011
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-73R Heat Timer EPU-CH Blue Panel REMANUFACTURED,
Item#:
C346-73R
Manufacturer Item:
C346-73R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C346-72R Heat Timer EPU Blue Panel REMANUFACTURED,
Item#:
C346-72R
Manufacturer Item:
C346-72R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C255-120R Commercial Defrost Timer, 208/240 volt, 40 amp, 4
Item#:
C255-120R
Manufacturer Item:
8045-20
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124E High Limit Triple Aquastat Relay, 120 VAC, SPST, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit
    Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water Mount directly to boiler
  • Select models include large transformers and extra terminals for supplying power to low voltage zone valves
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
Item#:
C317-7R
Manufacturer Item:
L8124E1016
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C255-132R Defrost Timer, 208/240 volt, 40 amp, 4 - 110 min in 2
Item#:
C255-132R
Manufacturer Item:
8141-20
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L8151A is a remote bulb controller for use with hydronic heating systems that include domestic hot water service.
    Provides high limit, low limit and circulator control for maintaining boiler temperatures
  • Can provide multizone control by using a separate thermostat and R845 Relay for each zone
  • An internal transformer powers the thermostat circuit
  • Shielded capillary allows convenient mounting
  • Consists of a diaphragm powerhead and micro switch assembly that responds to temperature changes in the boiler water
  • Mounting lugs on back of case
Item#:
C317-13R
Manufacturer Item:
L8151A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C317R Triple Aquastat, 110 - 220 deg F Low Limit, 130 - 240 deg F High Limit, 10 - 25 deg F Adjustable Low Limit, 10 deg F Fixed High Limit Differential, SPST, 120 VAC, Remanufactured
  • Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems, including domestic hot water
  • Provides multi zone control by using a separate circulator and relay for each zone
  • Includes diaphragm power head and Micro-Switch assembly that respond to temperature changes in boiler water
  • Mounts directly to boiler
  • Requires a 24 VAC thermostat with heat anticipator set at 0.2 ampSid Harvey Item #:C317R: Replaces Part #:'s : AQU8124A1007-C317-2B | C317-2B | C317-2R,
Item#:
C317R
Manufacturer Item:
L8024A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey L7224U oil electronic aquastat controller provides electronic temperature sensing in a UL limit-rated controller, controls the circulator, oil burner and boiler temperature, and provides status, LED diagnostic and EnviroCOM communication.
  • EnviraCOM, a low-cost 3-wire communication protocol that allows different devices, such as communicating thermostats, aquastats and oil primaries, to connect and share information Honeywell L7224U1002 Electronic Oil Aquastat, 120 VAC, 130 - 240 deg F High Limit, 110 - 220 deg F Low Limit , 5 - 20 deg F Fixed High Limit, 10 - 25 deg F Adjustable Low Limit Differential
Item#:
C317-14R
Manufacturer Item:
L7224U1002
Manufacturer:
SID HARVEY REMANUFACTURED
Honeywell L8124G1020 High Limit Triple Aquastat Relay, 120 VAC at 60 Hz, SPST
    Immersion-type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
  • Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
  • Include diaphragm powerhead and micro Switch assembly that respond to temperature changes in boiler water
  • Mount directly to boiler
  • Provide multi-zone control by using a separate circulator and R845 relay for each zone
  • Electrical burner rating: full load - 7.4 amp at 120 VAC line voltage, 3.7 amp at 240 VAC; locked rotor - 44.4 amp at 120 VAC line voltage, 22.7 amp at 240 VAC
  • Electrical circulator rating: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC full load; 44.4 amp at 120 VAC, 22.2 amp at 240 VAC locked rotor

Item#:
C317-8R
Manufacturer Item:
L8124G1020
Manufacturer:
SID HARVEY REMANUFACTURED
|◀ 97 - 108 of 192 ▶|
View: