S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-ScaleSid Harvey Item #:C290R: Replaces Part #:'s : AQU4006A1678-C290 | AQU4006A2007-C290A | C290 | C290A |,
,
,
Sid Harvey Remanufactured C290R
Item#:
C290R
Manufacturer Item:
L4006A1678-2007
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C255-140R Paragon Timer 8145-20 REMANUFACTURED,
,
,
Sid Harvey Remanufactured C255-140R
Item#:
C255-140R
Manufacturer Item:
8145-20
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D
- Pressure actuated high limit, safety control for steam heating boilers, It breaks an electrical circuit to shut down the burner if steam pressure rises above a safe level
- Contains an SPST Micro switch snap-acting switch
- Sensitive pressure actuated diaphragm expands or contracts with pressure variations, moving a lever mechanism which operates the snap switch
- A screw on top of the case allows setpoint adjustment without removing the cover
- Differential is adjusted by means of a dial located inside the case
- Recommended minimum setpoint is differential setting plus 1-1/2 psi
- Stainless steel diaphragm sensor element
- Makes at setpoint on pressure fall breaks at setpoint plus differential on pressure rise Honeywell Pressuretrol PA404A Pressure Controller with additive differential, 0.5 - 9 psi, 3-3/8 Inch W x 4-15/32 Inch H x 2-1/4 Inch D,
Sid Harvey Remanufactured C354R
Item#:
C354R
Manufacturer Item:
PA404A1033
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential
- Immersion-type controllers that combine high limit protection with switching relay control of burner and circulator motors
- High limit opens burner circuit only
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
- 1-1/2 - 3 Inch depth less well insulation
- Electrical burner rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC; millivolt: 0.25 amp at 1/4 - 12 VDC
- Electrical circulator rating: at full load: 7.4 amp at 120 VAC, 3.7 amp at 240 VAC; at locked rotor: 44.4 amp at 120 VAC, 22.2 amp at 240 VAC Honeywell L8148J1009/U Aquastat Relay, 120 VAC at 60 Hz, SPST, 120 - 240 deg F High Limit, 8 deg F Fixed Differential,
,
Sid Harvey Remanufactured C312-9R
Item#:
C312-9R
Manufacturer Item:
L8148J1009
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C346-58R Discharge Water Control, 80 - 220 deg F, 24/120/240,
,
,
Sid Harvey Remanufactured C346-70R
Item#:
C346-70R
Manufacturer Item:
C346-70R
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C255-138R Paragon Timer 8145-00 REMANUFACTURED,
,
,
Sid Harvey Remanufactured C255-138R
Item#:
C255-138R
Manufacturer Item:
8145-00
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C290R Aquastat, 100 - 240 deg F, 5 - 30 deg F Mid-Scale,
,
,
Sid Harvey Remanufactured C332-6R
Item#:
C332-6R
Manufacturer Item:
L6081A1010
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C293-3R Aquastat Immersion SPDT 100-240 Degrees REMANUFACTURED,
,
,
Sid Harvey Remanufactured C293-3R
Item#:
C293-3R
Manufacturer Item:
L6006A1145
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey C322-4R Dual Aquastat, 130 - 240 deg F High Limit, 110 - 220Sid Harvey Item #:C322-4R: Replaces Part #:'s : C322-4A,
,
,
Sid Harvey Remanufactured C322-4R
Item#:
C322-4R
Manufacturer Item:
L4081B1096-1047
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C255-110R Paragon Timer 8041-00 REMANUFACTURED,
,
,
Sid Harvey Remanufactured C255-110R
Item#:
C255-110R
Manufacturer Item:
8041-00
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell L8124A High and Low Limit Circulator Triple Aquastat Relay, 120 VAC, 130 - 240 deg F Adjustable High Limit, 110 - 220 deg F Adjustable Low Limit
,
- Immersion type controllers that combine high limit protection with low limit and circulator control in forced hydronic heating systems
- Provide multi-zone control by using a separate circulator and R845 relay for each zone
- Include diaphragm powerhead and micro switch assembly that respond to temperature changes in boiler water
- Mount directly to boiler
- Select models include large transformers and extra terminals for supplying power to low voltage zone valves
- Require 24 VAC thermostat with heat anticipator set at 0.2 amp (plus current draw of gas valve on L8124E)
,
Sid Harvey Remanufactured C317-2R
Item#:
C317-2R
Manufacturer Item:
L8124A1007,1015,1098
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured C434-12R Fan limit Control 8'' REMANUFACTURED,
,
,
Sid Harvey Remanufactured C434-12R
Item#:
C434-12R
Manufacturer Item:
C434-12R
Manufacturer:
SID HARVEY REMANUFACTURED
