Home  > BRADLEY-SCIOCCHETTI INC.(x)
View:
Standard Features:
  • 240V motor, 24V controls
  • Factory installed disconnect
  • Factory or field installed electric heat
  • Separate compartment for drain connections
  • Drain pan has 3/4" male or female primary and secondary fittings
  • High efficiency cooling coil
  • Convenient equalizer connection for factory or field installed R410A TXV's (non-bleed type)
  • Easily accessible 1" filter
  • Cabinet air leakage is no more than 2% when tested in accordance with ASHRAE 193
  • Item#:
    18UC5-R410TXV
    Manufacturer Item:
    64W1805V4
    Manufacturer:
    FIRST CO.
    First Company A/C Parts PL36059 Vertical Pan
    Item#:
    PL36059
    Manufacturer Item:
    PL36059
    Manufacturer:
    FIRST CO.
    First Company A/C Parts 967-PANEL Acess Panel Use #967-CP OR 967-1
    Item#:
    967-PANEL
    Manufacturer Item:
    967
    Manufacturer:
    FIRST CO.
    First Company A/C Parts E-141 Sequencer 24V Primary 1 switch 1 timing On: 30 90 seconds Off: 1 30 seconds
    Item#:
    E-141
    Manufacturer Item:
    E-141
    Manufacturer:
    FIRST CO.
    Item#:
    USM318AP
    Item#:
    E141
    First Company Motors M222 1-PH Blower Motor, 1/5 HP, 120 VAC
    Item#:
    M222
    Manufacturer Item:
    M222
    Manufacturer:
    FIRST CO.
    First Company A/C Parts CB201 Control Board
    Item#:
    CB201
    Manufacturer Item:
    CB201
    Manufacturer:
    FIRST CO.
    Multi-function micro-processor circuit board with these standard features:
  • Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
  • Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after thermostat is satisfied, for increased efficiency
  • 120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied motorized zone valves
  • Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
  • Manual Air Vent on hot water coil
  • Blower door shut-off switch (except 60/61HCXW (PSC))
  • Slide out hot water coil for easier service
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Attractive baked-on powder coated cabinet
  • Primary and secondary condensate drain connections
  • Easily accessible 1 filter
  • Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
  • Item#:
    24HCXW2V10AVB00AAF
    Manufacturer Item:
    6024W2V10AVB00AAF
    Manufacturer:
    FIRST CO.
    Multi-function micro-processor circuit board with these standard features:
  • Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
  • Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
  • Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after thermostat is satisfied, for increased efficiency
  • 120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied motorized zone valves
  • Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
  • Manual Air Vent on hot water coil
  • Blower door shut-off switch (except 60/61HCXW (PSC))
  • Slide out hot water coil for easier service
  • Copper tube heating and cooling coils
  • Compatible with all major brands of split condensing units and heat pumps
  • Attractive baked-on powder coated cabinet
  • Primary and secondary condensate drain connections
  • Easily accessible 1 filter
  • Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
  • Item#:
    24HCXW2010AVB00AAF
    Manufacturer Item:
    6024W2010AVB00AAF
    Manufacturer:
    FIRST CO.
    Item#:
    30HCXW2010AVB00AAF
    View: