Home  > CARLIN COMBUSTION TECHNOLOGY(x)
|◀ 121 - 132 of 159 ▶|
View:
Carlin 98630S Oil Burner Motor Permanent Split Capacitor Motor, 1/4 HP, 120 VAC, 3450 RPM
  • More efficient both starting and running
  • More reliable
  • Auto reset thermal overload
  • Quiet sealed ball bearings
  • Eliminates centrifuGallon start switch
  • More versatile
  • Replace 1/15 to 1/4 HP motors
  • Replaceable capacitor
  • Capacitor 9 location (looking from rear)
  • Requires 25 mfd capacitor
  • 10" lead length
,

carlin 98630s

,

98630S

Item#:
98630S
Manufacturer Item:
98630S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 98866S Oil Burner Motor Permanent Split Capacitor Motor, 1/6 HP, 120 VAC, 1725 RPM
  • More efficient both starting and running
  • More reliable
  • Auto reset thermal overload
  • Quiet sealed ball bearings
  • Eliminates centrifuGallon start switch
  • More versatile
  • Replace 1/15 to 1/4 HP motors
  • Replaceable capacitor
  • Capacitor 9 location (looking from rear)
  • Requires 14 mfd capacitor
  • 10" lead length
Sid Harvey Item #:98866S: Replaces Part #:'s : 4H448D,

98866S

,

98866S

Item#:
98866S
Manufacturer Item:
98866S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 98022S Oil Burner Motor Permanent Split Capacitor Motor, 1/7 HP, 120 VAC, 3450 RPM
  • More efficient both starting and running
  • More reliable
  • Auto reset thermal overload
  • Quiet sealed ball bearings
  • Eliminates centrifuGallon start switch
  • More versatile
  • Replace 1/15 to 1/4 HP motors
  • Replaceable capacitor
  • Capacitor 9 location (looking from rear)
  • Requires 16 mfd capacitor
  • 10" lead length
Sid Harvey Item #:98022S: Replaces Part #:'s : A39-31P | MOTO173450-21805U | 21805U,

98022S

,

carlin 98022s

Item#:
98022S
Manufacturer Item:
98022S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 380836 Oil Burner OH8 Furnace EZ-1 Carlin
    ,

    carlin parts 380836

Item#:
380836
Manufacturer Item:
380836
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 50200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
,

carlin parts r77-40

,

R77-40

Item#:
R77-40
Manufacturer Item:
5020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Combustion Technology, Inc. the industrys technological leader in oil and gas, residential and commercial burners, controls and igniters.
  • Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • LED indicators, alarm contacts and pump prime for economic as well as efficient performance
  • Serviceman reset protection ( latch-up after three consecutive lockouts)
  • 15 sec trial for ignition (TFI) other timings available
  • It offers recycle on flame failure and 1.3 sec flame failure response time
  • Oil primary control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 9 VA
  • It has a temperature rating of 32 - 140 deg F, resistive rating of 1500 ohm and safety switch timing of 15 sec
  • Primary control offers serviceman reset protection and valve delay on/motor delay off feature
  • It has a motor load of 10 FLA/60 LRA, ignitor load of 120 VAC at 60 Hz and valve load of 120 VAC at 60 Hz
  • 500 VA motor load
  • 24 VAC/VDC, 2 amp alarm contacts
  • Flame signal test jack
Sid Harvey Item #:R77-41: Replaces Part #:'s : 7G998,

carlin parts r77-41

,

R77-41

Item#:
R77-41
Manufacturer Item:
6020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 40200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Interrupted duty ignition
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • Recycle on flame failure
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
Sid Harvey Item #:R77-10: Replaces Part #:'s : 7G194,

R77-10

,

carlin parts r77-10

Item#:
R77-10
Manufacturer Item:
40200-02S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
  • Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • Valve delay on/motor delay off (pre/post-purge)
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
,

R77-44

,

R77-44

Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
  • Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • Diagnostic LED indicators
  • Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
  • Recycle on flame failure
  • It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
  • Valve delay on/motor delay off for economic as well as efficient performance
  • It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
  • 500 VA motor load
Sid Harvey Item #:R75-45: Replaces Part #:'s : 4H638,

carlin parts r75-45

,

R75-45

Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 70200S Universal Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Programmable, micro-processor based, universal replacement for CAD cell oil burner primary controls
  • Replaces Carlin, Beckett, Honeywell and ICM primary controls
  • On-board LCD screen no special tool needed
  • Valve delay on (0, 3, 10, 15, 30, 60, 120)
  • Trial for ignition time (15, 30, 45)
  • Motor delay off (0, 10, 15, 30, 120, 300, 900)
  • Interrupted or intermittent duty operation
  • Early spark termination timing (0, -5, -10)
  • Number of recycles (0, 3)
  • Serviceman reset protection
  • Blocked vent protection
  • Alarm contacts
  • Built-in pump prime
  • Fault history
,

carlin parts 70200s

,

70200S

Item#:
70200S
Manufacturer Item:
70200S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
  • 45 sec trial for ignition
  • Red LED lockout indicator
  • Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
  • 5 amp full load, 60 amp locked rotor motor load
  • 120 VAC, 60 Hz, 500 VA igniter load
Sid Harvey Item #:R75-47: Replaces Part #:'s : 7G193,

carlin parts r75-47

,

R75-47

Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 9780111JEC1 Oil Burner Weil McLain
    ,

    9780111JEC1

    ,

    9780111JEC1

Item#:
9780111JEC1
Manufacturer Item:
9780111JEC1
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
|◀ 121 - 132 of 159 ▶|
View: