Riello 3020503 Oil Pump for F3 - F15, M3 - M15 Burners


Riello Parts 3007567

Item#:
3020503
Manufacturer Item:
3020503
Manufacturer:
RIELLO CORP OF AMERICA
ICM Controls ICM1503 Intermittent Oil Primary Control, 120/240 VAC, Domestic
  • Intermittent ignition oil primary control with 45 sec safety timing, replacement for Honeywell R8184G Series
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with External reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models
Sid Harvey Item #:ICM1503: Replaces Part #:'s : R8184G1138,
,



ICM Controls ICM1502

Item#:
ICM1503
Manufacturer Item:
ICM1503
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM1502 Intermittent Oil Primary Control, 120/240 VAC, Domestic
  • Intermittent ignition oil primary control with 30 sec safety timing, replacement for Honeywell R8184G Series
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Enclosed safety switch with External reset butTon
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • Replacement for popular competitive models
,
,

ICM Controls ICM1501

Item#:
ICM1502
Manufacturer Item:
ICM1502
Manufacturer:
ICM INTERNATIONAL
Honeywell Protectorelay R8184G4066/U Non-Recycle Oil Burner Control with Safety Timing, 4-1/8" W x 4-3/8" H x 2-1/2" Depth
  • Provides automatic, non-recycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with External reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box (select models may be mounted directly on burner housing)
  • C554A cadmium sulfide flame detector and 24 volts thermostat required
  • 15 second safety timing, alarm outputs, and manual safety switch
  • Intermittent ignition timing
Sid Harvey Item #:R75-37: Replaces Part #:'s : R75-37R,
,



Carlin Parts R77-41

Item#:
R75-37
Manufacturer Item:
R8184G4066
Manufacturer:
HONEYWELL
Honeywell Protectorelay R8184G4082 Oil Burner Control
  • With 45 sec safety timing and alarm outputs
  • Provides automatic, nonrecycling control of an intermittent ignition oil burner system
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • Enclosed safety switch with External reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4" junction box, select models may be mounted directly on burner housing
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • 75 VA at 120/240 VAC, 50-60 Hz, 25 VA at 24V, 50-60 Hz alarm load ratings(pilot duty)
Sid Harvey Item #:R75-44: Replaces Part #:'s : L40-026,
,



honeywell r75-44

Item#:
R75-44
Manufacturer Item:
R8184G4082
Manufacturer:
HONEYWELL
Carlin Parts 42230-02S CAD Cell Oil Primary Control for Thermostat/Aquastat Compatible, 120 VAC, 500 watt
  • Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • Diagnostic LED indicators
  • Secondary burner control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 10 VA from limit circuit
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • 30 sec trial for Ignition 42230 (1.3 sec flame failure response time (FFRT)
  • Recycle on flame failure
  • It has a temperature rating of 32 - 140 deg F and resistive rating of 1500 ohm
  • Valve delay on/motor delay off for economic as well as efficient performance
  • It has a motor load of 10 FLA/60 LRA and ignitor load of 120 VAC at 60 Hz
  • 500 VA motor load
Sid Harvey Item #:R75-45: Replaces Part #:'s : 4H638,

,



Carlin Parts 70200S

Item#:
R75-45
Manufacturer Item:
4223002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell Protectorelay R8184M1051 Oil Burner Control for Boilers, 120 - 240 VAC
  • Operates the oil burner and oil valve (if desired) in response to a call for heat from a low voltage control circuit
  • Intermittent ignition is on while the burner is on
  • Solid state flame sensing circuit
  • External button to manually reset safety switch after lockout
  • Enclosed safety switch must be manually reset after safety shutdown
  • R8184M includes 40 VA transformer and Y and G terminals for connection of cooling equipment
  • Mounts on standard 4 x 4" junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
Sid Harvey Item #:R75-58: Replaces Part #:'s : R75-58R,

,



Honeywell R75-40

Item#:
R75-58
Manufacturer Item:
R8184M1051
Manufacturer:
HONEYWELL
Carlin Parts 40200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Interrupted duty ignition
  • 15 sec trial for Ignition 40200 (1.3 sec flame failure response time (FFRT))
  • Recycle on flame failure
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
Sid Harvey Item #:R77-10: Replaces Part #:'s : 7G194,
,



Carlin Parts R75-47

Item#:
R77-10
Manufacturer Item:
40200-02S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 6020002S015120 CAD Cell Oil Primary Control, 15 sec Trial
  • Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • Valve delay on/motor delay off (pre/post-purge)
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
,
,



carlin parts r77-44

Item#:
R77-44
Manufacturer Item:
6020002S015120
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts Combustion Technology, Inc. the industrys technological leader in oil and gas, residential and commercial burners, controls and igniters.
  • Interrupted duty ignition for high efficiency
  • SMC technology for safety monitoring
  • LED indicators, alarm contacts and pump prime for economic as well as efficient performance
  • Serviceman reset protection ( latch-up after three consecutive lockouts)
  • 15 sec trial for ignition (TFI) other timings available
  • It offers recycle on flame failure and 1.3 sec flame failure response time
  • Oil primary control has a input voltage rating of 120 VAC, input frequency rating of 60 Hz and input power rating of 9 VA
  • It has a temperature rating of 32 - 140 deg F, resistive rating of 1500 ohm and safety switch timing of 15 sec
  • Primary control offers serviceman reset protection and valve delay on/motor delay off feature
  • It has a motor load of 10 FLA/60 LRA, ignitor load of 120 VAC at 60 Hz and valve load of 120 VAC at 60 Hz
  • 500 VA motor load
  • 24 VAC/VDC, 2 amp alarm contacts
  • Flame signal test jack
Sid Harvey Item #:R77-41: Replaces Part #:'s : 7G998,
,



Carlin Parts R77-40

Item#:
R77-41
Manufacturer Item:
6020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Carlin Parts 50200-02S CAD Cell Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Interrupted duty ignition
  • Recycle on flame failure
  • Serviceman reset protection (latch-up after 3-consecutive lockouts)
  • Diagnostic LED
  • 15 sec trial for ignition (TFI) other timings available
  • 1.3 sec flame failure response time (FFRT)
  • Alarm contacts
  • Thermostat/aquastat compatible
  • SMC (safety monitoring circuit) technology
,
,



Carlin Parts R77-10

Item#:
R77-40
Manufacturer Item:
5020002S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Riello C7001010 Pump for F3, F5, F10, M3, M5 and M10 Oil Burner
Sid Harvey Item #:7001010: Replaces Part #:'s : 4H569,
,



Riello Parts 620-1

Item#:
7001010
Manufacturer Item:
7001010
Manufacturer:
RIELLO CORP OF AMERICA