|◀ 385 - 396 of 1140 ▶|
View:
Flow Rate
  • Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
Spray Angle
  • Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
Burner Air Patterns
  • Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer


1.10-90B

Item#:
1.10-90B
Manufacturer Item:
00110-90B1
Manufacturer:
DELAVAN SPRAY TECH
Item#:
1.75-45A
Flow Rate
  • Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
Spray Angle
  • Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
Burner Air Patterns
  • Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer


1.50-90A

Item#:
1.50-90A
Manufacturer Item:
00150-90A1
Manufacturer:
DELAVAN SPRAY TECH
Fasco A227 1-Speed Permanent Split Capacitor Draft Inducer Blower Motor, 1/25 HP, 115/1 VAC , 3450 RPM
  • Automatic thermally protected
Sid Harvey Item #:A227: Replaces Part #:'s : 70624708 | 70624708S | 37320717001 | 2427641000 | S137320717001 | x89-990 |,
,



fasco a227


fasco a227

Item#:
A227
Manufacturer Item:
A227
Manufacturer:
REGAL BELOIT AMERICA INC- FDC
Weil-McLain Heating Parts 315700100 Front Section 80 Series,
,



Weil-Mclain Heating Parts 315700100


Weil-Mclain Heating Parts 315700100

Item#:
315700100
Manufacturer Item:
315-700-100
Manufacturer:
WEIL-MCLAIN
Weil-McLain Heating Parts 315700140 Intermediate Section
,
,



315700140


315700140

Item#:
315700140
Manufacturer Item:
315-700-140
Manufacturer:
WEIL-MCLAIN
Weil-McLain Heating Parts 383300165 LGB Base End Panel

    ,
    ,



    Weil-Mclain Heating Parts 383300165


    Weil-Mclain Heating Parts 383300165

Item#:
383300165
Manufacturer Item:
383-300-165
Manufacturer:
WEIL-MCLAIN
Weil-McLain Heating Parts 383800101 Low Profile Boiler Stand

383800101

Item#:
383800101
Manufacturer Item:
383-800-101
Manufacturer:
WEIL-MCLAIN
Weil-McLain Heating Parts 383900126 Easy- Up 299-399 Ever Green Manifold,

383900126

Item#:
383900126
Manufacturer Item:
383-900-126
Manufacturer:
WEIL-MCLAIN
Weil-McLain Heating Parts 383900125 Evergreen 70-220 Manifold

383900125

Item#:
383900125
Manufacturer Item:
383-900-125
Manufacturer:
WEIL-MCLAIN
Weil-McLain Heating Parts 383700196 Gas Valve WM97+155

Weil-McLain Heating Parts 383700196

Item#:
383700196
Manufacturer Item:
383-700-196
Manufacturer:
HONEYWELL
Weil-McLain Heating Parts 383700195 Blower ECO 155 WM97+ WM97+CT Boilers

383700195

Item#:
383700195
Manufacturer Item:
383-700-195
Manufacturer:
WEIL-MCLAIN
|◀ 385 - 396 of 1140 ▶|
View: