S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Item#:
BCH0015MCACYA0100
Manufacturer Item:
BCH0015MCACYA0100
Manufacturer:
HEATCRAFT REFRIGERATION PROD,
Item#:
BCH0010MBACYA0100
Manufacturer Item:
BCH0010MBACYA0100
Manufacturer:
HEATCRAFT REFRIGERATION PROD,
Fujitsu General heating and cooling offers parts that are perfectly designed and engineered to fit your A/C and Heating Unit right the first time and deliver year-round comfort
K9322474001
Item#:
K9322474001
Manufacturer Item:
9322474001
Manufacturer:
FUJITSU
Item#:
0018E-2F2
Manufacturer Item:
0018E-2F2
Manufacturer:
TACO INC.
LCFO-92-W
Hart & Cooley 0.012" Aluminum Inner and 0.018" G90 Galvanized Steel
- Deep locking groove assures solid joint and secure lock
- Corrosion resistant aluminum inner wall for rapid warm-up
- Unique locking band provides 360 deg turning radius of the pipe and fittings
- Locking band slides over tabs easily, locks firmly without twisting
- Locking tabs hold pipe securely together, can be easily unlocked
- Positive stop provides proper alignment and positive fit for mating end of pipe or fitting
- Reinforced ends curled bead on end of outer pipe for rigidity and strength
- The allowable minimum clearance to combustibles is 1"
- A full set of installation instructions are supplied with caps and supports Hart & Cooley 10RP3 B-Vent Pipe 10" x 36" Natural Gas Aluminum Inner & Galvanized Steel Outer,
10RP5
10RP5
Item#:
10RP5
Manufacturer Item:
2001614
Manufacturer:
HART & COOLEY, LLC.
Viessmann Parts 7830 016 Combination Chamber Refractory For Vitodens 100-W/200-W Series Boilers
7830016
Item#:
7830016
Manufacturer Item:
7830016
Manufacturer:
VIESSMANN MANUFACTURING INC.
Hart & Cooley 821 Bright White Enamel Steel Vertical Blade Adjustable,
,
,
HC8216X6
HC8216X6
Item#:
HC8216X6
Manufacturer Item:
075001
Manufacturer:
HART & COOLEY, LLC.
Flow Rate
- Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
- Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
- Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer
1.35 GPH 1.35-90B
Item#:
1.35-90B
Manufacturer Item:
00135-90B1
Manufacturer:
DELAVAN SPRAY TECH
Weil-McLain Heating Parts 383500135 Front Dorr Assembly Ultra
383500135
Item#:
383500135
Manufacturer Item:
383500135
Manufacturer:
WEIL-MCLAIN
Sid Harvey R. D. Bitzer 18001 Pump Housing for 3 Inch Self-Priming Centrifugal Pumps
- R. D. Bitzer 18001 Pump Housing for 3 Inch Self-Priming Centrifugal Pumps,
P400R
Flow Rate
- Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
- Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
- Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer
