Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
24HCXW2010AVB00AAF
Item#:
24HCXW2010AVB00AAF
Manufacturer Item:
6024W2010AVB00AAF
Manufacturer:
FIRST CO.
Multi-function micro-processor circuit board with these standard features:
Blower start relay - Eliminates field installed boiler relay, allowing direct wiring from the boiler to the air
handler
Blower-on fan delay - (heating mode) - preheats the HW coil for 45 seconds.
Blower-off fan delay - (heating and cooling models) - blower continues to operate for 45 seconds after
thermostat is satisfied, for increased efficiency
120V or 24V zone valve control - The micro-pro-cessor powers either 120V or 24V field supplied
motorized zone valves
Factory or field installed R-410A TXV (cooling or heat pump operation) (non-bleed type)
Manual Air Vent on hot water coil
Blower door shut-off switch (except 60/61HCXW (PSC))
Slide out hot water coil for easier service
Copper tube heating and cooling coils
Compatible with all major brands of split condensing units and heat pumps
Attractive baked-on powder coated cabinet
Primary and secondary condensate drain connections
Easily accessible 1 filter
Cabinet air leakage is no more the 2% when tested in accordance with ASHRAE 193
First Company 30HCXW2010AVB00AAF
Item#:
30HCXW2010AVB00AAF
Manufacturer Item:
6030W2010AVB00AAF
Manufacturer:
FIRST CO.
Advance Distributers BCRMA7624-S2N4 Air Handler
- Multi-Position 1-1/2-2 Ton 115 VAC 3 Speed Motor TxV R22,
,
Advance Distributers BCRMA3124-S03
Item#:
BCRMA7624-S2N4
Manufacturer Item:
BCRMA7624-S2N4
Manufacturer:
ADVANCED DISTRIBUTOR PRODUCTS
FEATURES
Environmentally Balanced Refrigerant Technology
R-410A, chlorine-free, non-ozone depleting refrigerant
Thermostatic Expansion Valve (TXV) designed to maximize
performance with R-410A refrigerant
Energy Efficient Operation
Variable Speed Constant Airflow ECM (Electronically Commutating
Motor) operates efficiently at all speeds
Maximizes efficiency of heating and cooling systems
Ultra low power consumption during fan only operation
Indoor Weather Control
Warm, comfortable heating air temperatures
Unmatched humidity control, especially with thermostat with relative
humidity controls
Airflow and Sound Technology
Diffuser air discharge section for high airflow efficiency and quiet,
smooth operation
High duct static capability
Design meets stringent regulations for cabinet air leakage of less than
2% when tested at 0.5 inches W.C., and cabinet air leakage less than
1.4% at 0.5 inches W.C. when tested in accordance with ASHRAE
193 standard.
Condensate Control and Disposal Technology
Minimal standing waterless microbial growth for improved IAQ and
reduced condensate line clogging and related condensate leakage
Condensate fittings relocated away from turbulent airflow patterns at
the blower entrance for improved condensate control performance
Overflow feature for slope coil units allows condensate to exit the unit
without damage to product under clogged primary and secondary line
conditions
Tested for condensate disposal at conditions much more severe than
those required by AHRI
Primary and secondary drain connections to comply with HUD
All pans constructed of an injection molded glass-filled polycarbonate
engineered resin material, with brass drain connections.
High density, super thick cabinetry insulation with vapor barrier
Indoor Weather Control
engineered resin material, with brass drain connections.
International Comfort Products FTMA4B60L0DA
Item#:
FTMA4X24L0BA
Manufacturer Item:
FTMA4X24L0BA
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
International Comfort Products FXM4X3000AL
Item#:
FXM4X4800AL
Manufacturer Item:
FXM4X4800AL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
INTERNATIONAL COMFORT PRODUCTS FXM4X4200AL
Item#:
FXM4X4200AL
Manufacturer Item:
FXM4X4200AL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
Fujitsu FH3017TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
- 30K BTU 3 Ton
- 208/230/1 VAC
- 17" Wide
- PCS Motor
- Multi-Position,
,
Fujitsu FH2417TTSJSN
Item#:
FH3017TPSJSN
Manufacturer Item:
FH3017TPSJSN
Manufacturer:
FUJITSU
Fieldpiece Instruments S365 Charging JacketCharging Jacket is a reliable way to charge TXV systems in cold weather. Normally, low temperatures remove too much heat from the condenser coils, so HVACR professionals should only work on TXV systems when the outside air temperature is 70 deg F or higher. Now, the new Fieldpiece Charging Jacket solves that problem, and TXV systems can be accurately charged down to 37 deg F outside temps. It's the perfect tool to dramatically extend the hours in a day, and the days in a year, where techs can install, service, and charge TXV systems. Made from parachute-grade material, the Charging Jacket is attached to the top of a split TXV system with hooks, so that the air inlet is not restricted. Then the unit is turned on the jacket puffs up from the air being forced out of the air outlet. The top is then adjusted with a drawstring until the proper pressure differential is reached between the high and low side (between 160 psi and 220 psi for R410A; and between 100 psi and 145 psi for R22). Once the systems stabilizes for 15 minutes at the correct pressure differential, the system is ready to be charged.
,
- Charge TXV systems in cold weather
- Charge TXV systems from 37 - 70 deg F outside
- Service maintenance contracts before and after the summer heat
- Easy to adjust to reach correct pressure differential
- Great way to increase business during the slow season
- Field tested for accuracy
- Looks professional
- Extend billable hours
- There is no other product on the market made specifically for this purpose
- Currently, HVACR professionals either do not work on TxV systems if it is below 70 deg F outside, or, if it's an emergency techs might use their actual jackets or cardboard to block the air inlet
- The problem is those methods are inaccurate
- The charging jacket's advantage is that it works to bring the pressure drop across the TxV to at least 160 psi and therefore has the same effect on the system as higher temperatures do
- HVACR professionals can now dramatically extend their billable hours because they can work on systems during the off season
- So instead of having the do service contract check-ups during the summer rush, service and maintenance can be start early in the spring, and continue late into the fall
- And even year-round in many parts of the country
- Parachute grade
,
Fieldpiece Instruments S365
Fieldpiece Instruments S365
Baked-On Powder Coated Hydronic Air Handler with TXV Metering
- Multi function micro-processor circuit board
- Blower start relay - eliminates field installed boiler relay, allowing direct wiring from the boiler to the air handler
- Manual air vent on hot water coil
- Blower door shut-off switch
- Slide out hot water coil for easier service
- 2-speed fan operation
- Convertible horizontal drain pan
- PisTon type metering device (standard)
- Copper tube heating and cooling coils
- Compatible with all major brands of split condensing units and heat pumps
- Primary and secondary condensate drain connections
- Factory installed filter drier
- 1" filter easily accessible
- Without pump
First Company 48HCXW3X10AVB00AAF
Item#:
60HCXB-HW-R410A-TXV
Manufacturer Item:
6060H3HW4X
Manufacturer:
FIRST CO.
ALL MODELS:
11/2 thru 5 Tons
Copper tube / aluminum fin A coil with latest
hightech fin design
Bolton TXV metering device factory installed on all
models (equalizer tube brazed in)
TXV and manifold positioned to the side for easier
cleaning
Innovative drain pan design for complete water
removal
Two condensate drain connections
(EDM has additional two for horizontal installation)
2piece delta plate for easier removal and cleaning
CASED COILS
Upflow cabinet widths and horizontal cabinet depths
match flush with ICP gas furnaces
Removable front access panel
Easy slideout coil for inspection
Hemmed flanges for safer handling
Foil faced insulation
Nonsweat cabinet, even at extreme conditions
Cabinets meet or exceed 2% air leakage codes
Sturdy, 22 gauge, prepainted steel cabinet
EDM
Multiposition installation upflow, downflow, or
horizontal
Available for R410A
(EDM tincoated available for R22 systems)
Two UV light knockouts provided on cabinet
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
EDD
Upflow or downflow installation
Available for R410A
Two UV light knockouts provided on cabinet
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
UNCASED ACOILS
EDA
Upflow or downflow installation
Available for R410A systems
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
EDA
International Comfort Products EDM4X24FAL
Item#:
EDM4X36JAL
Manufacturer Item:
EDM4X36JAL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
ALL MODELS:
11/2 thru 5 Tons
Copper tube / aluminum fin A coil with latest
hightech fin design
Bolton TXV metering device factory installed on all
models (equalizer tube brazed in)
TXV and manifold positioned to the side for easier
cleaning
Innovative drain pan design for complete water
removal
Two condensate drain connections
(EDM has additional two for horizontal installation)
2piece delta plate for easier removal and cleaning
CASED COILS
Upflow cabinet widths and horizontal cabinet depths
match flush with ICP gas furnaces
Removable front access panel
Easy slideout coil for inspection
Hemmed flanges for safer handling
Foil faced insulation
Nonsweat cabinet, even at extreme conditions
Cabinets meet or exceed 2% air leakage codes
Sturdy, 22 gauge, prepainted steel cabinet
EDM
Multiposition installation upflow, downflow, or
horizontal
Available for R410A
(EDM tincoated available for R22 systems)
Two UV light knockouts provided on cabinet
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
EDD
Upflow or downflow installation
Available for R410A
Two UV light knockouts provided on cabinet
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
UNCASED ACOILS
EDA
Upflow or downflow installation
Available for R410A systems
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
EDA
International Comfort Products EDM4X24BAL
Item#:
EDM4X24FAL
Manufacturer Item:
EDM4X24FAL
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
ALL MODELS:
11/2 thru 5 Tons
Copper tube / aluminum fin A coil with latest
hightech fin design
Bolton TXV metering device factory installed on all
models (equalizer tube brazed in)
TXV and manifold positioned to the side for easier
cleaning
Innovative drain pan design for complete water
removal
Two condensate drain connections
(EDM has additional two for horizontal installation)
2piece delta plate for easier removal and cleaning
CASED COILS
Upflow cabinet widths and horizontal cabinet depths
match flush with ICP gas furnaces
Removable front access panel
Easy slideout coil for inspection
Hemmed flanges for safer handling
Foil faced insulation
Nonsweat cabinet, even at extreme conditions
Cabinets meet or exceed 2% air leakage codes
Sturdy, 22 gauge, prepainted steel cabinet
EDM
Multiposition installation upflow, downflow, or
horizontal
Available for R410A
(EDM tincoated available for R22 systems)
Two UV light knockouts provided on cabinet
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
EDD
Upflow or downflow installation
Available for R410A
Two UV light knockouts provided on cabinet
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
UNCASED ACOILS
EDA
Upflow or downflow installation
Available for R410A systems
Available with industry exclusive tin coated copper
main tubing for additional corrosion protection
EDA
ICP Fast Motors 1083044
Item#:
EDM4X36FAL
Manufacturer Item:
EDM4X36FAL