The 50A65-5165 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporates system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction. it is designed as a replacement for the following controls.
  • Twinning connection
  • Fused to protect low VAC age system transformers
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • 1 micro-amp DC minimum current
  • 0.10 micro-amp DC max current
  • 100 mega-ohm leakage resistance
  • Maximum timing specification
  • 0.8 sec flame establishing
  • 2 sec flame failure response time
  • 77 deg F electrical rating
  • Flash code diagnostics, controls gas valve, igniter, blower, inducer, 120 VAC humidifier and air cleaner
Sid Harvey Item #:50A65-5165: Replaces Part #:'s : CNT05165 | CNT5165 |,


white rodgers 50a65-5165


white rodgers 50a65-5165

Item#:
50A65-5165
Manufacturer Item:
50A65-5165
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50U-843 Universal Intermittent Pilot All Spark 24V Ignition Module, White Rodgers 50D50U-843

White Rodgers 50D50U-843

Item#:
50D50U-843
Manufacturer Item:
50D50U-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E47-843 Silicon Carbide Universal Non-Integrated Hot Surface Ignition Control Kit, 18 - 30 VAC, 0.2 amp
  • Program keys for easy customization
  • Tri-color LED indicator for diagnostics
  • Direct and indirect flame sense
  • Replaces all White Rodgers Cooling Controls 50E47-xxx modules and virtually all competitive silicon carbide, non-integrated modules
  • 6 amp at 120 VAC, 60 Hz resistive igniter relay
  • Includes program keys, mounting hardware, double-sided foam back tape (for ease of installation), extensive cross-reference guide, color-coded timing label, pre-printed hanging carTon, instructions in english/instructions en espanol
  • 95% RH non-condensing humidity range
Sid Harvey Item #:50E47-843: Replaces Part #:'s : HS780-17NL-104A | HS780-17NL-106A | HS780-17NL-108A | HS780-17NL-304A | HS780-17NL-306A | HS780-17NL-308A | HS780-17NR-104A | HS780-17NR-106A | HS780-17NR-108A | HS780-17NR-304A | HS780-17NR-306A | HS780-17NR-308A | HS780-17NR-312A | HS780-17PL-106A | HS780-17PL-108A | HS780-17PL-304A | HS780-17PL-306A | HS780-17PL-308A | HS780-17PR-104A | HS780-17PR-108A | HS780-17PR-306A | HS780-34NL-106A | HS780-34NL-108A | HS780-34NL-304A | HS780-34NL-306A | HS780-34NL-308A | HS780-34NL-312A | HS780-34NR-104A | HS780-34NR-106A | HS780-34NR-304A | HS780-34NR-306A | HS780-34NR-308A | HS780-34NR-312A | HS780-34PL-104A | HS780-34PL-106A | HS780-34PL-108A | HS780-34PL-304A | HS780-34PL-306A | HS780-34PL-308A | HS780-34PR-106A | HS780-34PR-108A | HS780-34PR-304A | HS780-34PR-306A | HS780-34PR-308A |,
Item#:
50E47-843
Manufacturer Item:
50E47-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 5059-134 Pilot Relite Control, 24 VAC, 0.03 amp
  • Generates spark pulse until flame is sensed through spark electrode
  • Begins sparking immediately if flame extinguishes
  • Rugged solid state module design
  • Spike terminal high voltage and 1/4" spade terminals connection
Sid Harvey Item #:5059-134: Replaces Part #:'s : CNT01011,


white rodgers 5059-134


white rodgers 5059-134

Item#:
5059-134
Manufacturer Item:
5059-134
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50E70-820 HSI Integrated Furnace Control, 18 - 30 VAC, 60 Hz
  • 1-stage applications
  • 120 volt HSI ignition
  • Adapter board and harness included
  • For packaged units
  • Flame current test pins
  • Red and green status LEDs
  • Standoffs/adapter board mounting
  • 0.8 sec flame establishing time, 2 sec flame failure response time at 60 Hz
  • Flame current requirements - minimum current to insure flame detection: 1 micro-amp DC, maximum current for non-detection: 0.1 micro-amp DC, maximum allowable leakage resistance: 100 mega-ohm,



    50E70-820


    50E70-820

Item#:
50E70-820
Manufacturer Item:
50E70-820
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-842 Universal DSI Control for Gas-Fired Non-Integrated Forced Air Furnaces, Boilers, 25 VAC, 0.2 amp, 4.13" W x 4.13" H x 1-1/2" D
  • Color LED indicator for diagnostics
  • Includes program keys, double-sided foam back tape, color coded timing label, pre-printed hanging carTon
  • 1/4 and 3/16" quick connect terminals
  • Direct and indirect flame senseSid Harvey Item #:50D50-842: Replaces Part #:'s : DS845 780-502 | DS845 780-504 |,



    50D50-842


    50D50-842

Item#:
50D50-842
Manufacturer Item:
50D50-842
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50M56-743 Hot Surface Igniter Nitride Integrated Furnace Control, 25 VAC, 0.45 amp, 50/60 Hz
  • System diagnostic LED with fault recall
  • Multi speed circulator
  • 1 or 2-stage gas valve
  • Relay load ratings - 1.5 amp at 25 VAC 50/60 Hz 0.6 pico-F valve relay, 6 amp at 120 VAC 50/60 Hz (resistive) igniter relay, 2.2 amp full load, 3.5 amp locked rotor at 120 VAC inducer relay, 14.5 amp full load, 25 amp locked rotor at 120 VAC circulator relay
  • Flame current requirements - 1 micro-amp DC minimum current to insure flame detection, 0.10 micro-amp DC maximum current for non-detection, 100 mega-ohm maximum allowable leakage resistance
  • 0.8 sec flame establishing time, 2 sec flame failure response time
,


white rodgers 50m56-743


white rodgers 50m56-743

Item#:
50M56-743
Manufacturer Item:
50M56-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
The 50A66-743 is an automatic gas interrupted ignition control that employs a microprocessor to continually monitor, analyze, and control the proper operation of the gas burner, inducer, and fan. signals interpreted during continual surveillance of the thermostat and flame sensing element initiate automatic ignition of the burner, sensing of the flame, and system shutoff during normal operation. these controls incorporate system fault analysis for quick gas flow shutoff , coupled with automatic ignition retry upon sensing a fault correction.
  • 3-fan speeds
  • Remote flame sensing
  • Humidifier and electronic air cleaner connections (optional)
  • 1.5 amp valve relay
  • 6 amp igniter relay
  • 2.2 amp full load - 3.5 amp locked rotor inducer relay
  • 14.5 amp full load - 25 amp locked rotor circulator relay
  • Diagnostic indicator flash codes, controls gas valve, igniter, blower, inducer, humidifier and air cleaner
Sid Harvey Item #:50A66-743: Replaces Part #:'s : 100925-01 | 100925-02 | 100925-03 | 10092501 | 10092502 | 10092503 |,
Item#:
50A66-743
Manufacturer Item:
50A66-743
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 50D50-801 Pilot Spark Ignition Control for Gas Appliance 18-30 VAC 0.2 amp,



50D50-801


50D50-801

Item#:
50D50-801
Manufacturer Item:
30W33
Manufacturer:
WHITE-RODGERS DIV OF COPELAND

White Rodgers 57T01-843

Item#:
57T01-843
Manufacturer Item:
57T01-843
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 768A Silicon Nitride Hot Surface Ignitor, 80 volt, 2.16" L Lead
White Rodgers 768A-815

White Rodgers 768A-815

Item#:
768A-815
Manufacturer Item:
768A-815
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
White Rodgers Cooling Controls 768A-842 Silicon Nitride Natural/LP Gas Hot Surface Igniter, 120 volt
    2-terminal AMP receptacle, 0.093 female sockets
  • White teflon coated leads
  • Steatite Insulator With Steel Zinc Plated Mounting Tabs
  • Must be used with hot surface ignition for 120 volt residential furnaces (silicon nitride replacement only)

    768A-842

Item#:
768A-842
Manufacturer Item:
768A-842
Manufacturer:
WHITE-RODGERS DIV OF COPELAND
|◀ 1261 - 1272 of 1299 ▶|