S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
Heatcraft Motors 25309501S Fan Motor
- 1/15 HP 1300/1600 RPM 120 VAC,
Item#:
25309501S
Manufacturer Item:
25309501S
Manufacturer:
HEATCRAFT REFRIGERATION PROD,
Heatcraft Motors 25308601S Fan Motor 1/15 HP 1400/1650 230 VAC 5/16" Shaft
Item#:
25308601S
Manufacturer Item:
25308601S
Manufacturer:
HEATCRAFT REFRIGERATION PROD,
Carlin Parts 23150S Universal Flange Gasket, 3" ID
Item#:
616-90
Manufacturer Item:
23150S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Space Pak BM-3001 Fiberboard Square Duct Plenum 8" x 4', Gallonvanized,
Item#:
BM-3001
Manufacturer Item:
44BM-2560
Manufacturer:
SPACE PAK
Beckett Parts CG4001 Chassis for CG4 Gas Conversion Burner
Item#:
CG4001
Manufacturer Item:
CG4
Manufacturer:
RW BECKETT CORP
Airex Filters Pleated Air Filter 14" x 25" x 2"
How often do I need to change my air filter?
There are many factors that can determine when an air filter should be changed. How often the HVAC unit runs, air quality, humidity
and other factors can vary greatly from application to application. For most 1, 2 and 4 deep panel or pleated style filters, it is usually
recommended to change the filter every 2-3 months. In many commercial and industrial applications static pressure can be monitored
and the filters can be changed when they reach their recommended final resistance in inches of water gauge.
What is MERV?
MERV stands for: Minimum Efficiency Reporting Value. MERV is part of the ASHRAE 52.2 Test Standard that determines the
ability of an air filter to remove particles of a specific size from an air stream. Air filters can have a MERV of 1 to 16; the higher the
MERV, the more efficient the filter is at capturing particles.
Watts Water LF3001A-3/4 Dielectric Union 3/4" FPT x Sweat
dielectric unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metals and is used on applications such as hot water storage tanks, water and air conditioners, processing tanks, steam, gas, and water piping. It consists of a female iron pipe thread to solder connection, union nut, two tailpieces, and a Buna-N gasket that separates the tailpieces to prevent an electric current from occurring.
dielectric unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metals and is used on applications such as hot water storage tanks, water and air conditioners, processing tanks, steam, gas, and water piping. It consists of a female iron pipe thread to solder connection, union nut, two tailpieces, and a Buna-N gasket that separates the tailpieces to prevent an electric current from occurring.
- Buna-N gasket Designed and manufactured to the highest quality standards
- Maximum pressure is 250 psi (17.2 bar)
- Maximum temperature 180 degrees F (82 degrees C)
- Individually factory certified to withstand a minimum of 600 volts on a dry line with no flashover
- FIP thread to solder connections
- Meets federal specifications for tensile strength and thread end connections,
Watts Water LF3001A-1/2 Dielectric Union 1/2" OD x FPT Lead-Free,
Item#:
LF3001A-1/2
Manufacturer Item:
0009864
Manufacturer:
WATTS REGULATOR CO
Watts Water LF3001A-1-1/4 Dielectric Union 1-1/4" FPT x OD Lead Free
dielectric unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metals and is used on applications such as hot water storage tanks, water and air conditioners, processing tanks, steam, gas, and water piping. It consists of a female iron pipe thread to solder connection, union nut, two tailpieces, and a Buna-N gasket that separates the tailpieces to prevent an electric current from occurring.
dielectric unions are used in commercial and residential applications to prevent accelerated corrosion and deterioration in the piping system due to galvanic and stray current. It is installed between pipes made from dissimilar metals and is used on applications such as hot water storage tanks, water and air conditioners, processing tanks, steam, gas, and water piping. It consists of a female iron pipe thread to solder connection, union nut, two tailpieces, and a Buna-N gasket that separates the tailpieces to prevent an electric current from occurring.
- Buna-N gasket Designed and manufactured to the highest quality standards
- Maximum pressure is 250 psi (17.2 bar)
- Maximum temperature 180 degrees F (82 degrees C)
- Individually factory certified to withstand a minimum of 600 volts on a dry line with no flashover
- FIP thread to solder connections
- Meets federal specifications for tensile strength and thread end connections,
Item#:
LF3001A-1-1/4
Manufacturer Item:
00098867
Manufacturer:
WATTS REGULATOR CO
Watts Water LF3001A-1 Dielectric Union 1" FPT x Sweat Brass
Features/Benefits
One-piece heating and cooling units with low sound levels, easy
installation, low maintenance, and dependable performance.
R-454B is the latest choice of refrigerant to help meet the 2025 GWP
requirement. This unit is designed and tested with R-454B and contains
a dissipation system.
Easy Installation
Factory-assembled package is a compact, fully self-contained,
combination gas heating/electric cooling unit that is prewired, pre-piped,
and pre-charged for minimum installation expense. These units are
available in a variety of standard and optional heating/ cooling size
combinations with voltage options to meet residential and light
commercial requirements. Units are lightweight and install easily on a
rooftop or at ground level. The high tech composite base eliminates rust
problems associated with ground level applications.
Innovative Unit Base Design
On the inside a high-tech composite material will not rust and
incorporates a sloped drain pan which improves drainage and helps
inhibit mold, algae and bacterial growth. On the outside metal base rails
provide added stability as well as easier handling and rigging.
Convertible duct configuration
Unit is designed for use in either downflow or horizontal applications.
Each unit is converted from horizontal to downflow and includes two
horizontal duct covers. Downflow operation is provided in the field to
allow vertical ductwork connections. The basepan seals on the bottom
openings to ensure a positive seal in the vertical airflow mode.
Efficient operation High-efficiency design offers SEER2 (Seasonal
Energy Efficiency Ratios) of 13.4, 11.05 EER2, and AFUE (Annual Fuel
Utilization Efficiency) ratings of 81.0%.
Energy-saving, direct spark ignition saves gas by operating only when
the room thermostat calls for heating. Standard units are furnished with
natural gas controls. A low-cost field installed kit for propane
conversion is available for all units.
Low NOx units meet 40 ng/J NOx emissions. Can be installed in air
quality management districts with a 40 ng/J NOx emissions requirement.
Durable, dependable components
Monoport inshot burners produce precise air-to-gas mixture, which
provides for clean and efficient combustion. The large monoport on the
inshot (or injection type) burners seldom, if ever, requires cleaning. All
gas furnace components are accessible in one compartment.
Turbo-tubular heat exchangers are constructed of stainless steel for
corrosion resistance and optimum heat transfer for improved efficiency.
The tubular design permits hot gases to make multiple passes across the
path of the supply air.
In addition, dimples located on the heat exchanger walls force the hot
gases to stay in close contact with the walls, improving heat transfer.
ECM Motor is standard on all models.
Direct-drive PSC (Permanent Split Capacitor) condenser-fan
motors are designed to help reduce energy consumption and provide for
cooing operation down to 40°F (4.4°C) outdoor temperature.
Motormaster® II low ambient kit is available as a field-installed
accessory.
Thermostat controls
Time Guard® II anti-short cycle protection circuitry. If a non-corporate
thermostat without anti-short cycle protection is used the Time Guard II
field-installed anti-short cycle kit is recommended.
Refrigerant system is designed to provide dependability. Liquid filter
driers are used to promote clean, unrestricted operation. Each unit leaves
the factory with non-ozone depleting and low global warming potential
R-454B refrigerant charge. Refrigerant service connections make
checking operating pressures easier. Factory-installed leak detection
dissipation system for added safety.
High Pressure Switch provides added reliability for the compressor.
Item#:
PGB448130L001B
Manufacturer Item:
PGB448130L000B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FPPF Chemical 00119 Killem Biocide Treatment,