Carlin Parts R77-32 Ignitor Carlin,
,



Carlin Parts R77-24

Item#:
R77-32
Manufacturer Item:
41000S0CAS
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell AT140A1000 General Purpose Transformer, 40 VA, 120 VAC Primary, 24 VAC, 27V Open Circuit Secondary, 60 Hz
  • Includes fixed 1/4" male quick-connects or color-coded lead wires for primary and secondary connections
  • Includes metal end bells
Sid Harvey Item #:T394-62: Replaces Part #:'s : 12139,
,



Honeywell AT175F1023

Item#:
T394-62
Manufacturer Item:
AT140A1000
Manufacturer:
HONEYWELL
Streamline Copper Solder-Joint Fittings for supply/pressurized systems have been the leading brand of copper fittings for decades. Our product selection has grown to become the most extensive in the industry. We are the acknowledged experts at engineering and manufacturing precision solder-joint copper fittings. Quality, consistency and reliability have made the Streamline brand trusted and specified all around the world.

W13-6

Item#:
W13-6
Manufacturer Item:
W 61000
Manufacturer:
COPPER FITTINGS
Streamline W1-396 Insulated Copper Line 1/2" x 1/2" x 100'
Streamline line sets have been an industry leader for decades. We leverage our many years of experience and expertise producing copper tube in every line set we make. From liquid line and suction line handling to unique insulation applications and packaging, every Streamline line set meets our rigorous standards for quality and consistency. With a broad offering of liquid line and suction line diameters, insulation, thicknesses, custom ends and connections plus a wide array of custom options, we're able to meet our customers most specialized and exacting needs.
  • Proprietary manufacturing process allows for kink-free installation
,
,



Mueller Line Sets W1-395

Item#:
W1-396
Manufacturer Item:
00821000
Manufacturer:
LINE SETS
Streamline W1-394 Insulated Copper Line 1/4" x 1/2" x 100'
Streamline line sets have been an industry leader for decades. We leverage our many years of experience and expertise producing copper tube in every line set we make. From liquid line and suction line handling to unique insulation applications and packaging, every Streamline line set meets our rigorous standards for quality and consistency. With a broad offering of liquid line and suction line diameters, insulation, thicknesses, custom ends and connections plus a wide array of custom options, we're able to meet our customers most specialized and exacting needs.
  • Proprietary manufacturing process allows for kink-free installation
,
,



Mueller Line Sets W1-385

Item#:
W1-394
Manufacturer Item:
00421000
Manufacturer:
LINE SETS
Streamline W1-395 Insulated Copper Line 3/8" x 1/2" x 100'
Streamline line sets have been an industry leader for decades. We leverage our many years of experience and expertise producing copper tube in every line set we make. From liquid line and suction line handling to unique insulation applications and packaging, every Streamline line set meets our rigorous standards for quality and consistency. With a broad offering of liquid line and suction line diameters, insulation, thicknesses, custom ends and connections plus a wide array of custom options, we're able to meet our customers most specialized and exacting needs.
  • Proprietary manufacturing process allows for kink-free installation
,
,



Mueller Line Sets W1-394

Item#:
W1-395
Manufacturer Item:
00621000
Manufacturer:
LINE SETS
Bosch ZWB28-3 Combi Gas Boiler 100K,95%,
,



Bosch ZBR42-3

Item#:
ZWB28-3
Manufacturer Item:
7738100002
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Flow Rate
  • Atomizing nozzles are available in a wide range of flow rates, all but eliminating the need for specially calibrated nozzles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
  • Spray angles are available from 30° through 90° in most nozzle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° nozzles. Long, narrow chambers usually require 30° to 60° spray angles.
  • Burner Air Patterns
  • Burner air patterns are much like nozzle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel nozzle. A burner with a solid air pattern will give highest efficiency with a solid cone nozzle, but the flame will probably be longer.



    10.00 GPH 10.00-45B

  • Item#:
    10.00-45P
    Manufacturer Item:
    10.00-45P
    Manufacturer:
    MONARCH NOZZLES
    Flow Rate
  • Atomizing nozzles are available in a wide range of flow rates, all but eliminating the need for specially calibrated nozzles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
    Spray Angle
  • Spray angles are available from 30° through 90° in most nozzle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° nozzles. Long, narrow chambers usually require 30° to 60° spray angles.
  • Burner Air Patterns
  • Burner air patterns are much like nozzle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel nozzle. A burner with a solid air pattern will give highest efficiency with a solid cone nozzle, but the flame will probably be longer.



    10.00 GPH 10.00-60B

  • Item#:
    10.00-60P
    Manufacturer Item:
    10.00-60P
    Manufacturer:
    MONARCH NOZZLES
    3M Venture Tape1599B-2 Excellent as a Flexible duct closure tape (Black) 2" x 120 Yards


    3M 1581A

    Item#:
    1599B-2
    Manufacturer Item:
    7100043760
    Manufacturer:
    3M
    3M Venture Tape Flue Pipe Tape 3" x 50 Yards (Silver)



    3M 1599B-2

    Item#:
    3243
    Manufacturer Item:
    7100043878
    Manufacturer:
    GTA-NHT, INC
    Honeywell ST9120U1011 Universal Electronic Fan Timer For Control of Combustion Blower for a Gas Warm Air Appliances, 18 - 30 VAC
    • Replaces 40+ existing Resideo electronic fan timers
    • Instruction sheet supplies full cross reference and wiring guide
    • Interface harnesses for simple conversion
    • Dip switch selectable heat and cool delay on and off times
    • Electronic air cleaner and humidifier terminal connections
    • Continuous low speed indoor air circulation
    • Integrates control of all combustion blower and circulating fan operations in gas warm-air appliance
    • Replaceable fuse
    • Heat fan on delay - adjustable 30, 60 sec ( set at 30 sec)
    • Heat fan off delay - adjustable 60, 120, 150, 180 sec (set at 120 sec)
    • Cool fan on delay - adjustable 4, 30 sec (set at 4 sec)
    • Cool fan off delay - adjustable 30, 60 sec (set at 30 sec)
    Sid Harvey Item #:ST9120U1011: Replaces Part #:'s : ST9101A1014 | ST9101A1022 | ST9120A2004 | ST9120C2002 | ST9120C2010 | ST9120C3000 | ST9120C3018 | ST9120C4008 | ST9120C4016 | ST9120C4040 | ST9120C4057 | ST9120C5005 | ST9120C5013 | ST9120D3009 | ST9120G2024 | ST9120G4004 | ST9120G4038 | ST9120U1003 | ST9141A1002 | ST9141A1028 | ST9141B1001 | ST9150A1003 | ST9150B2000 | ST9150B2018 | ST9150B2026 | ST9150C4057 | ST9160A1002 | ST9160B1001 | ST9160B1019 | ST9160B1027 | ST9160B1035 | ST9160B1043 | ST9160B1050 | ST9160B1068 | ST9160B1076 | ST9160C1000 | ST9160C1018,
    ,



    Honeywell R841C1227

    Item#:
    ST9120U1011
    Manufacturer Item:
    ST9120U1011
    Manufacturer:
    HONEYWELL
    |◀ 265 - 276 of 400 ▶|