The class II Model 610 Digital Current Monitor offers the latest
technology for providing positive and accurate over current motor
(load) protection for single, and 3 phase motors, drawing between 5
and 200 amps. The Model 610 also can monitor up to two thermistor
temperature sensors to detect abnormally high and/or low compressor
operating temperatures.
Motor protection is accomplished by monitoring the operating
motor current, in each phase of the load, using current transformers.
For both single and 3 phase loads, the control digitally processes the
sampled current and calculates the excess energy being absorbed by
the motor due to current flow above the operator selected trip level.
If the current is above the selected trip level, the controller calculates
the excess power and integrates to calculate excess energy. When the
excess energy rises to a level equivalent to locked rotor for 2 seconds,
a current trip will occur. If the current drops below the trip level prior
to a trip, the controller will reset the integration to zero. This prevents
false-alarm trips. Fail-safe operation is provided by protecting the load
from excessive current or abnormal temperatures in one or more of
the following overload conditions:
If one of the above conditions occurs, the Model 610 operates a TRIP relay to disconnect power from the load. An ALARM relay is also provided that can be used to alert operators of a lockout condition. The number of automatic trip resets allowed before a lockout occurs is operator selectable. The automatic trip reset time is also selectable. When protecting 3 phase loads, the Model 610 detects phase
imbalance and can also verify correct phase rotation during each load's startup. Setting the current trip level at 8% above the nominal FLA of the motor will indirectly provide both low and high voltage protection. Setting the current trip level at other percentage levels above FLA will directly protect the motor. The optional, customer supplied, Omega 10K thermistor temperature sensors can be used to monitor compressor exhaust temperature and crankcase oil temperature. Omega offers a wide range of thermistor sensors that are readily available. The trip temperature values are operator selectable. The Exhaust high temperature value can be set between 80°F and 300°F or between 100 Ohms and 20K Ohms. The Oil temperature trip values can be set for high, low or both high and low trip temperatures between 20°F and 200°F or between 200 Ohms and 20K Ohms. Consult factory for different temperature ranges.
If one of the above conditions occurs, the Model 610 operates a TRIP relay to disconnect power from the load. An ALARM relay is also provided that can be used to alert operators of a lockout condition. The number of automatic trip resets allowed before a lockout occurs is operator selectable. The automatic trip reset time is also selectable. When protecting 3 phase loads, the Model 610 detects phase
imbalance and can also verify correct phase rotation during each load's startup. Setting the current trip level at 8% above the nominal FLA of the motor will indirectly provide both low and high voltage protection. Setting the current trip level at other percentage levels above FLA will directly protect the motor. The optional, customer supplied, Omega 10K thermistor temperature sensors can be used to monitor compressor exhaust temperature and crankcase oil temperature. Omega offers a wide range of thermistor sensors that are readily available. The trip temperature values are operator selectable. The Exhaust high temperature value can be set between 80°F and 300°F or between 100 Ohms and 20K Ohms. The Oil temperature trip values can be set for high, low or both high and low trip temperatures between 20°F and 200°F or between 200 Ohms and 20K Ohms. Consult factory for different temperature ranges.
Hoffman Controls 610-3PH
Item#:
610-3PH
Manufacturer Item:
610-3PH
Manufacturer:
HOFFMAN CONTROLS CORP.
AG2403C3
Item#:
AG2403C3
Manufacturer Item:
AG2403C3
Manufacturer:
INTERMATIC USD
Littelfuse 250A
Intermatic AG3000
Item#:
AG3000
Manufacturer Item:
AG3000
Manufacturer:
INTERMATIC USD
Intermatic CD1-024R
Item#:
CD1-024R
Manufacturer Item:
CD1-024R
Manufacturer:
INTERMATIC USD
Detek DTK-CM
Item#:
DTK-CM
Manufacturer Item:
PSP72KA
Manufacturer:
DIVERSITECH CORP.
D10829-499
Item#:
D10829-499
Manufacturer Item:
ICM450C
Manufacturer:
ICM INTERNATIONAL
SPECIFICATIONS
Service voltage: 120/240 volt, single phase
Maximum surge current: 100,000 amps
Maximum energy dissipation: 1,020 Joules
Installation point: Electrical panel, electrical disconnect
Diagnostics: Green light indicates surge suppression present
AC protection modes: L-L, L-N, L-G, N-G
Conduit connection: 3/4
ICM Controls ICM517A
Item#:
ICM517A
Manufacturer Item:
ICM517A
Manufacturer:
ICM INTERNATIONAL
Product Features:
Reduces in-rush current/draw necessary at startup by up to 70%
Prolong the life of the A/C by reducing excessive torque, wear and tear
Reduce loud noises, light flickering, and breaker trips
Built-in self-learning algorithm
Over-current protection
Over/under voltage monitoring
Built-in start capacitor
LED fault indicators
Ultrasonic sealed tamper-proof enclosure
Installation hardware is included
ICM Controls ICM870-32A
Item#:
ICM870-32A
Manufacturer Item:
ICM870-32A
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM402
Item#:
ICM402
Manufacturer Item:
ICM402
Manufacturer:
ICM INTERNATIONAL
ICM Controls ICM401
Item#:
ICM401
Manufacturer Item:
ICM401
Manufacturer:
ICM INTERNATIONAL
ICM516
Item#:
ICM516
Manufacturer Item:
ICM516
Manufacturer:
ICM INTERNATIONAL