Flow Rate
- Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
- Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
- Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer
7747028943
Item#:
7747028943
Manufacturer Item:
7-747-028-943
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Flow Rate
- Atomizing noz.zles are available in a wide range of flow rates, all but eliminating the need for specially calibrated noz.zles. Between 1.00 GPH and 2.00 GPH, for example, seven different flow rates are available. Generally, with hot water and warm air heat, the smallest firing rate that will adequately heat the house on the coldest day is the proper size to use and the most economical. Short on-cycles result in low efficiency. Another guideline is to select the flow rate that provides a reasonable stack temperature regardless of the connected load. (According to the New England Fuel Institute, aim for a stack temperature of 400°F or lower on matched packaged units or 500°F or lower on conversion burners.) If the boiler or furnace is undersized for the load, it may be necessary to fire for the load and ignore the efficiency
- Spray angles are available from 30° through 90° in most noz.zle sizes to meet the requirements of a wide variety of burner air patterns and combustion chambers. Usually it is desirable to fit the spray angle to the air pattern of the burner. In todays flame retention burner, it is possible to fire more than one spray angle with good results. Generally, round or square combustion chambers should be fired with 70° to 90° noz.zles. Long, narrow chambers usually require 30° to 60° spray angles.
- Burner air patterns are much like noz.zle spray patterns in that they fall into the same general classifications, either hollow or solid. As you would expect, a burner with a hollow air pattern generally requires a hollow cone fuel noz.zle. A burner with a solid air pattern will give highest efficiency with a solid cone noz.zle, but the flame will probably be longer
7747028944
Item#:
7747028944
Manufacturer Item:
7-747-028-944
Manufacturer:
BOSCH THERMOTECHNOLOGY CORP
Lynn Superwool Plus 9600 Ceramic High Temperature Fiber Paper, 2000 deg F
Lynn Products 9600LY
Item#:
9600LY
Manufacturer Item:
9600
Manufacturer:
LYNN MANUFACTURING, INC.
Beckett Parts 511 Fusible fire safety valves are designed to reduce fire damage by shutting off the flow of oil from the oil tank in the event of a fire. They are required by code in residential oil heating installations in conformance with NFPA 31. All valves are embossed with an arrow indicating the direction of oil flow. The seal stem uses a double seal washer/O-Ring system with high grade Viton equivalent materials suitable for number 2 fuel oil and kerosene.
Beckett Parts 511
Item#:
511
Manufacturer Item:
B-105-F
Manufacturer:
RW BECKETT CORP
Time Saving Devices 550-38 Straight Tank Fill Adapter 1-1/2" Female,
550-38
Item#:
550-38
Manufacturer Item:
2150FXC
Manufacturer:
TIME SAVING FILLS INC
Item#:
2340034233
Manufacturer Item:
2340034233
Manufacturer:
ROTH INDUSTRIES