Brand Name
Type
Amperage
Voltage
|◀ 1 - 12 of 145 ▶|
View:
Diversitech 7-CRNR30 Class RK5 Dual Element Current-Limiting Time-Delay Fuse, 30 amp, 250 VAC
  • Eliminates unnecessary maintenance from harmless overloads
Sid Harvey Item #:E356-42: Replaces Part #:'s : 6546
Item#:
E356-42
Manufacturer Item:
ECNR-30
Manufacturer:
COOPER BUSSMAN LLC
Diversitech 626-AT0003 Purple Blade End Fast-Acting Auto Fuse, 3 amp
  • Low VAC age supplementary
Sid Harvey Item #:EFATC3: Replaces Part #:'s : 6505
Item#:
EFATC3
Manufacturer Item:
626-AT0003
Manufacturer:
DIVERSITECH CORP
Bussmann ATC-5 Lead Free Polycarbonate Blade End Fast Acting Fuse, 5 amp, 32 VDC, Tan
  • Halogen free
  • Tin plated zinc terminal and element for corrosion resistance and enhanced conductivity
  • Industry standard color coding for quick identification of amp rating
Sid Harvey Item #:ATC-5: Replaces Part #:'s : 6506
Item#:
ATC-5
Manufacturer Item:
626-AT0005
Manufacturer:
COOPER BUSSMAN LLC
Siemens ITEQ220 Plug-In Mount 2-Pole Type QP Circuit Breaker, 20 amp, 120/240 VAC , 10 kilo-amp Interrupt
  • Requires (2) 1" spaces
Item#:
ITEQ220
Manufacturer Item:
ITEQ220
Manufacturer:
CONNECTICUT ELECTRIC INC.
Diversitech 7-CRNR25 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 25 amp, 250 VAC
  • Provides time delay for temporary over-current conditions and motor running protection
  • Eliminates unnecessary maintenance from harmless overloads
Sid Harvey Item #:E356-41A: Replaces Part #:'s : 6545
Item#:
E356-41A
Manufacturer Item:
ECNR-25
Manufacturer:
COOPER BUSSMAN LLC
Diversitech 7-CRNR20 Dual Element Class RK5 Current-Limiting Time-Delay Fuse, 20 amp, 250 VAC
  • Provides time delay for temporary over-current conditions and motor running protection
  • Eliminates unnecessary maintenance from harmless overloads
Sid Harvey Item #:E356-41: Replaces Part #:'s : 6543
Item#:
E356-41
Manufacturer Item:
ECNR-20
Manufacturer:
COOPER BUSSMAN LLC
Sid Harvey E397-213 Plastic ATO Fuse, 3 amp
Item#:
E397-213
Manufacturer Item:
E397-213
Manufacturer:
SID HARVEY INDUSTRIES INC.
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
  • True dual-element construction allows sizing of 125% FLA for motor backup protection
  • Superior overload and cycling capabilities
  • Provides motor overload, ground fault and short-circuit protection
  • Helps protect motors against burnout from overloads and also from single phasing on three phase systems
  • Current limiting provides component short circuit protection
  • Simplifies and improves blackout prevention
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
  • The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Sid Harvey Item #:E356-43: Replaces Part #:'s : 6548
Item#:
E356-43
Manufacturer Item:
ECNR-40
Manufacturer:
COOPER BUSSMAN LLC
Sid Harvey E397-214 Plastic ATO Fuse, 5 amp
Item#:
E397-214
Manufacturer Item:
E397-214
Manufacturer:
SID HARVEY INDUSTRIES INC.
Recommended for AC power distribution system mains, feeders and branch circuits having inductive loads motors, transformers or non-inductive loads lighting, heating, typically allows them to be sized closer to the running ampacity of inductive loads to reduce cost and provide improved overcurrent protection, override normal equipment current surges to reduce unnecessary fuse openings.
  • True dual-element construction allows sizing of 125% FLA for motor backup protection
  • Superior overload and cycling capabilities
  • Provides motor overload, ground fault and short-circuit protection
  • Helps protect motors against burnout from overloads and also from single phasing on three phase systems
  • Current limiting provides component short circuit protection
  • Simplifies and improves blackout prevention
  • Dual-element fuses can be applied in circuits subject to temporary motor overloads and surge currents to provide both high performance, short circuit and overload protection
  • The overload element provides protection against low level over current of overloads and will hold an overload which is five times greater than the ampere rating of the fuse for a minimum of ten seconds
Sid Harvey Item #:E356-45: Replaces Part #:'s : 6551
Item#:
E356-45
Manufacturer Item:
ECNR-60
Manufacturer:
COOPER BUSSMAN LLC
Bussmann SA-15 Brass Screw Mount Fuse Adapter, 125 VAC , 15 amp, 3" W x 0.88" H x 2-1/4" D
Sid Harvey Item #:SA-15E: Replaces Part #:'s : G31-271
Item#:
SA-15E
Manufacturer Item:
SA-15
Manufacturer:
COOPER BUSSMAN LLC
Diversitech 626-15S Dual Element Non-Tamper Plug Time-Delay Fuse, 15 amp
  • Provides specific over current protection
  • Time-delay element protects against premature blowing from motors in air conditioners or compressors
  • Visual indication of good or blown condition
Sid Harvey Item #:E356-23: Replaces Part #:'s : 6595
Item#:
E356-23
Manufacturer Item:
626-15S
Manufacturer:
COOPER BUSSMAN LLC
|◀ 1 - 12 of 145 ▶|