S2K Commerce - Products Dropdown
S2K Commerce - Shopping Cart
S2K Commerce - Order Entry
International Comfort Products F97CMN0602120B
Item#:
F97CMN0801714B
Manufacturer Item:
F97CMN0801714B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
Quiet performance
Variable-speed, constant airflow (VCA) ECM blower motor and two-stage gas valve also provide enhanced levels of temperature control and comfort
Dual fuel capable with a compatible heat pump and thermostat for energy-saving heating performance
Fully insulated cabinet helps keep the heat moving to your ductwork
Air purifier and humidifier compatible
Wi-Fi enabled remote access with the Ion System Control
10-Year No Hassle Replacement Limited Warranty
10-Year Parts Limited Warranty upon timely registration
Lifetime Heat Exchanger Limited Warranty upon timely registration
International Comfort Products F80CTL0901716A
Item#:
F80CTL1352422B
Manufacturer Item:
F80CTL1352422B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
International Comfort Products F97CMN0601714B
Item#:
F97CMN0602120B
Manufacturer Item:
F97CMN0602120B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
International Comfort Products G96CTN0801714B
Item#:
G96CTN0802120B
Manufacturer Item:
G96CTN0802120B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
International Comfort Products G96CTN0802120B
Item#:
G96CTN1202422B
Manufacturer Item:
G96CTN1202422B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
International Comfort Products G97CMN0802120A
Item#:
G97CMN0802120A
Manufacturer Item:
G97CMN0802120A
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
INTERNATIONAL COMFORT PRODUCTS G97CMN0802120B
Item#:
G97CMN0802120B
Manufacturer Item:
G97CMN0802120B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
l
INTERNATIONAL COMFORT PRODUCTS G80CTL0701412B
Item#:
G80CTL0701412B
Manufacturer Item:
G80CTL0701412B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FEATURES:
Up to 96% AFUE in upflow and horizontal positions
95% AFUE in downflow position
All models earn the ENERGY STAR®
Two-stage heating operation
Variable-speed, constant torque ECM blower motor for extra SEER boost with select cooling equipment
Supports single- and two-stage cooling units
Dehumidification feature in cooling
Low NOx units are designed for California installations and meet
40 ng/J NOx emissions. Can be installed in air quality management
districts with a 40 ng/J NOx emissions requirement.
Cabinet air leakage less than 2.0% at 1.0 in. W.C. and
cabinet air leakage less than 1.4% at 0.5 in. W.C.
when tested in accordance with ASHRAE standard 193
TOUGHER
Flame roll-out sensors standard
Adjustable heating blower OFF delay
Factory set blower ON delay
RPJ primary heat exchanger
Stainless steel secondary heat exchanger
High temperature limit control prevents overheating
Direct ignition with Silicon Nitride ignitor
QUIETER
Operates at quieter, lower heating rates
Two-speed induced draft combustion motor
Variable speed, constant torque ECM blower motor
Fully insulated steel cabinet
EASIER TO INSTALL AND SERVICE
Direct vent (2-pipe), single-pipe venting or ventilated combustion air
24 VAC humidifier terminal and electronic air cleaner terminal
35 (889mm) high, for ease of installation
Quarter turn knobs for easy door removal and secure attachment
conversion kits available
Four position upflow/downflow/horizontal (left/right) installation
At least twelve different venting configurations
Through the casing flue pipe for counterflow or
horizontal applications with accessory (order separately)
Concentric vent available
Slide out heat exchanger assembly and blower assembly
International Comfort Products G96VTN1002120B
Item#:
G96VTN1202422A
Manufacturer Item:
G96VTN1202422A
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FEATURES:
Up to 96% AFUE in upflow and horizontal positions
95% AFUE in downflow position
All models earn the ENERGY STAR®
Two-stage heating operation
Variable-speed, constant torque ECM blower motor for extra SEER boost with select cooling equipment
Supports single- and two-stage cooling units
Dehumidification feature in cooling
Low NOx units are designed for California installations and meet
40 ng/J NOx emissions. Can be installed in air quality management
districts with a 40 ng/J NOx emissions requirement.
Cabinet air leakage less than 2.0% at 1.0 in. W.C. and
cabinet air leakage less than 1.4% at 0.5 in. W.C.
when tested in accordance with ASHRAE standard 193
TOUGHER
Flame roll-out sensors standard
Adjustable heating blower OFF delay
Factory set blower ON delay
RPJ primary heat exchanger
Stainless steel secondary heat exchanger
High temperature limit control prevents overheating
Direct ignition with Silicon Nitride ignitor
QUIETER
Operates at quieter, lower heating rates
Two-speed induced draft combustion motor
Variable speed, constant torque ECM blower motor
Fully insulated steel cabinet
EASIER TO INSTALL AND SERVICE
Direct vent (2-pipe), single-pipe venting or ventilated combustion air
24 VAC humidifier terminal and electronic air cleaner terminal
35 (889mm) high, for ease of installation
Quarter turn knobs for easy door removal and secure attachment
conversion kits available
Four position upflow/downflow/horizontal (left/right) installation
At least twelve different venting configurations
Through the casing flue pipe for counterflow or
horizontal applications with accessory (order separately)
Concentric vent available
Slide out heat exchanger assembly and blower assembly
International Comfort Products G96VTN1202422A
Item#:
G96VTN1202422B
Manufacturer Item:
G96VTN1202422B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
INTERNATIONAL COMFORT PRODUCTS G97CMN0801714B
Item#:
G97CMN0801714B
Manufacturer Item:
G97CMN0801714B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
FEATURES:
Up to 96% AFUE in upflow and horizontal positions
95% AFUE in downflow position
All models earn the ENERGY STAR®
Two-stage heating operation
Variable-speed, constant torque ECM blower motor for extra SEER boost with select cooling equipment
Supports single- and two-stage cooling units
Dehumidification feature in cooling
Low NOx units are designed for California installations and meet
40 ng/J NOx emissions. Can be installed in air quality management
districts with a 40 ng/J NOx emissions requirement.
Cabinet air leakage less than 2.0% at 1.0 in. W.C. and
cabinet air leakage less than 1.4% at 0.5 in. W.C.
when tested in accordance with ASHRAE standard 193
TOUGHER
Flame roll-out sensors standard
Adjustable heating blower OFF delay
Factory set blower ON delay
RPJ primary heat exchanger
Stainless steel secondary heat exchanger
High temperature limit control prevents overheating
Direct ignition with Silicon Nitride ignitor
QUIETER
Operates at quieter, lower heating rates
Two-speed induced draft combustion motor
Variable speed, constant torque ECM blower motor
Fully insulated steel cabinet
EASIER TO INSTALL AND SERVICE
Direct vent (2-pipe), single-pipe venting or ventilated combustion air
24 VAC humidifier terminal and electronic air cleaner terminal
35 (889mm) high, for ease of installation
Quarter turn knobs for easy door removal and secure attachment
conversion kits available
Four position upflow/downflow/horizontal (left/right) installation
At least twelve different venting configurations
Through the casing flue pipe for counterflow or
horizontal applications with accessory (order separately)
Concentric vent available
Slide out heat exchanger assembly and blower assembly
International Comfort Products G80VTL0701716B
Item#:
G96VTN0401410B
Manufacturer Item:
G96VTN0401410B
Manufacturer:
INTERNATIONAL COMFORT PRODUCTS
