  • Up to 97% AFUE in upflow/horizontal, up to 95% AFUE in downflow
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Supports single-stage cooling units
  • Insulated heat exchanger compartmen
    t
  • All sizes can be installed in air quality management districts with a 40 ng/J
  • NOx emissions requirement
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for twinning applications (0601716, 0801716, 0802120, 1002120, 1202422, 1402422) with accessory (order separately)
  • Approved for manufactured housing/mobile home applications (0401410 through 1202422) with accessory (order separately)

    International Comfort Products N96MSN1202422A

  • Item#:
    N96MSN1202422A
    Manufacturer Item:
    N96MSN1202422A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features/Benefits
  • One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. R-454B is the latest choice of refrigerant to help meet the 2025 GWP requirement. This unit is designed and tested with R-454B and contains a dissipation system.
  • Easy Installation
  • Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design
  • On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration
  • Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design offers SEER2 (Seasonal Energy Efficiency Ratios) of 13.4, 11.05 EER2, and AFUE (Annual Fuel Utilization Efficiency) ratings of 81.0%.
  • Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
  • Low NOx units meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Durable, dependable components
  • Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
  • Turbo-tubular heat exchangers are constructed of stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
  • In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.
  • ECM Motor is standard on all models.
  • Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field-installed accessory.
  • Thermostat controls
  • Time Guard® II anti-short cycle protection circuitry. If a non-corporate thermostat without anti-short cycle protection is used the Time Guard II field-installed anti-short cycle kit is recommended.
  • Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with non-ozone depleting and low global warming potential R-454B refrigerant charge. Refrigerant service connections make checking operating pressures easier. Factory-installed leak detection dissipation system for added safety. High Pressure Switch provides added reliability for the compressor.
  • Item#:
    PGB448115L000B
    Manufacturer Item:
    PGB448115L000B
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Up to 97% AFUE in upflow/horizontal, up to 95% AFUE in downflow
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Supports single-stage cooling units
  • Insulated heat exchanger compartmen
    t
  • All sizes can be installed in air quality management districts with a 40 ng/J
  • NOx emissions requirement
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for twinning applications (0601716, 0801716, 0802120, 1002120, 1202422, 1402422) with accessory (order separately)
  • Approved for manufactured housing/mobile home applications (0401410 through 1202422) with accessory (order separately)

    International Comfort Products N96MSN0802120A

  • Item#:
    N96MSN0802120A
    Manufacturer Item:
    N96MSN0802120A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features/Benefits
  • One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. R-454B is the latest choice of refrigerant to help meet the 2025 GWP requirement. This unit is designed and tested with R-454B and contains a dissipation system.
  • Easy Installation
  • Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design
  • On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration
  • Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design offers SEER2 (Seasonal Energy Efficiency Ratios) of 13.4, 11.05 EER2, and AFUE (Annual Fuel Utilization Efficiency) ratings of 81.0%.
  • Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
  • Low NOx units meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Durable, dependable components
  • Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
  • Turbo-tubular heat exchangers are constructed of stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
  • In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.
  • ECM Motor is standard on all models.
  • Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field-installed accessory.
  • Thermostat controls
  • Time Guard® II anti-short cycle protection circuitry. If a non-corporate thermostat without anti-short cycle protection is used the Time Guard II field-installed anti-short cycle kit is recommended.
  • Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with non-ozone depleting and low global warming potential R-454B refrigerant charge. Refrigerant service connections make checking operating pressures easier. Factory-installed leak detection dissipation system for added safety. High Pressure Switch provides added reliability for the compressor.
  • Item#:
    PGB448130H001B
    Manufacturer Item:
    PGB448130H001B
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features/Benefits
  • One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. R-454B is the latest choice of refrigerant to help meet the 2025 GWP requirement. This unit is designed and tested with R-454B and contains a dissipation system.
  • Easy Installation
  • Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design
  • On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration
  • Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design offers SEER2 (Seasonal Energy Efficiency Ratios) of 13.4, 11.05 EER2, and AFUE (Annual Fuel Utilization Efficiency) ratings of 81.0%.
  • Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
  • Low NOx units meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Durable, dependable components
  • Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
  • Turbo-tubular heat exchangers are constructed of stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
  • In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.
  • ECM Motor is standard on all models.
  • Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field-installed accessory.
  • Thermostat controls
  • Time Guard® II anti-short cycle protection circuitry. If a non-corporate thermostat without anti-short cycle protection is used the Time Guard II field-installed anti-short cycle kit is recommended.
  • Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with non-oz.one depleting and low global warming potential R-454B refrigerant charge. Refrigerant service connections make checking operating pressures easier. Factory-installed leak detection dissipation system for added safety. High Pressure Switch provides added reliability for the compressor.

    PGB430060K000B

  • Item#:
    PGB430060K000B
    Manufacturer Item:
    PGB430060K000B
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features/Benefits
  • One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. R-454B is the latest choice of refrigerant to help meet the 2025 GWP requirement. This unit is designed and tested with R-454B and contains a dissipation system.
  • Easy Installation
  • Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design
  • On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration
  • Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design offers SEER2 (Seasonal Energy Efficiency Ratios) of 13.4, 11.05 EER2, and AFUE (Annual Fuel Utilization Efficiency) ratings of 81.0%.
  • Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
  • Low NOx units meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Durable, dependable components
  • Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
  • Turbo-tubular heat exchangers are constructed of stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
  • In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.
  • ECM Motor is standard on all models.
  • Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field-installed accessory.
  • Thermostat controls
  • Time Guard® II anti-short cycle protection circuitry. If a non-corporate thermostat without anti-short cycle protection is used the Time Guard II field-installed anti-short cycle kit is recommended.
  • Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with non-ozone depleting and low global warming potential R-454B refrigerant charge. Refrigerant service connections make checking operating pressures easier. Factory-installed leak detection dissipation system for added safety. High Pressure Switch provides added reliability for the compressor.
  • Item#:
    PGB436060L001B
    Manufacturer Item:
    PGB436060L001B
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    REFRIGERATION CIRCUIT
  • Environmentally sound R410A refrigerant
  • Scroll compressor standard on all models
  • Copper tube/aluminum fin condenser and evaporator coils
  • Dehumidification mode (airflow reduction) on all models EASY TO INSTALL AND SERVICE
  • Installs easily on a rooftop or at ground level
  • Easy threepanel accessibility for maintenance and installation
  • Easily converts to down discharge applications
  • Combination gas heating, heat pump heating, and electric cooling
  • Low NOx units available BUILT TO LAST
  • Hail guard (3/8 spacing) wire grilles standard on PDS models (2 spacing wire grilles on PDD models)
  • Induceddraft combustion and venting
  • Prepainted steel cabinet
  • Aluminized steel tubular heat exchanger on PDD4 models, Stainless Steel tubular heat exchanger on PDS4 models
  • Direct spark ignition
  • High efficiency ECM indoor blower motor on all models
  • Vertical condenser fan discharge
  • Full perimeter steel base rails
  • High and low pressure switches provide added reliability for the compressor
  • PDS4 models come with tincoated copper evaporator coil standard

    PDD430060K000K

  • Item#:
    PDD430060K000K
    Manufacturer Item:
    PDD430060K000K
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Up to 96% AFUE in upflow and horizontal positions up to 95% AFUE in downflow position
  • FixedSpeeds, Constant Torque ECM blower motor
  • Supports singlestage cooling units
  • Insulated heat exchanger compartment
  • Approved for Twinning application (0601714 through 1002120) with accessory (order separately)
  • Approved for Manufactured Housing/Mobile Home applications (0401410 through 1202422) with accessory (order separately)
  • Low NOx units are designed for California installations and meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193
  • Item#:
    N95ESN0802120A
    Manufacturer Item:
    N95ESN0802120A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Up to 97% AFUE in upflow/horizontal, up to 95% AFUE in downflow
  • Multi 18-speed, constant torque (MCT) ECM blower motor
  • Enhanced diagnostics with easy to read 3 digit display for faults and status
  • Supports single-stage cooling units
  • Insulated heat exchanger compartmen
    t
  • All sizes can be installed in air quality management districts with a 40 ng/J
  • NOx emissions requirement
  • Cabinet air leakage less than 2.0% at 1.0 in. w.c. and cabinet air leakage less than 1.4% at 0.5 in. w.c. when tested in accordance with ASHRAE standard 193
  • Approved for twinning applications (0601716, 0801716, 0802120, 1002120, 1202422, 1402422) with accessory (order separately)
  • Approved for manufactured housing/mobile home applications (0401410 through 1202422) with accessory (order separately)

    N96MSN1402422A

  • Item#:
    N96MSN1402422A
    Manufacturer Item:
    N96MSN1402422A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features/Benefits
  • One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance.
  • R-454B is the latest choice of refrigerant to help meet the 2025 GWP requirement. This unit is designed and tested with R-454B and contains a dissipation system.
  • Easy Installation.
  • Factory-assembled package is a compact, fully self-contained, combination gas heating/electric heating and cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design
  • On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging.
    Convertible Duct Configuration
  • Unit is designed for use in either downflow or horizontal applications.
  • Each unit is converted from horizontal to downflow and includes horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode.
  • Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
  • Low NOx units are designed for California installations and meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement. Durable, dependable components
  • Scroll Compressors are designed for high efficiency. Each compressor is hermetically sealed against contamination to help promote longer life and dependable operation. Each compressor also has vibration isolation to provide quieter operation. All compressors have internal high pressure and overcurrent protection.
  • Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
  • Turbo-tubular heat exchangers are constructed of stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
  • In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer. ECM Motor is standard on all models.
  • Direct-drive, PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooling operation down to 40°F (4.4°C) outdoor temperature. Low ambient kit is available as a field installed accessory.
  • Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with non-ozone depleting and low global warming potential R-454B refrigerant charge. Refrigerant service connections make checking operating pressures easier. Factory-installed leak detection dissipation system for added safety High and Low Pressure Switches provide added reliability for the compressor.
  • Indoor and Outdoor coils are computer-designed for optimum heat transfer and efficiency. The indoor coil is fabricated from aluminum indoor coils and aluminum fins and is located inside the unit for protection against damage. The outdoor coil is internally mounted on the top tier of the unit
  • Item#:
    PDB448090K000B
    Manufacturer Item:
    PDB448090K000B
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Features/Benefits
  • One-piece heating and cooling units with low sound levels, easy installation, low maintenance, and dependable performance. R-454B is the latest choice of refrigerant to help meet the 2025 GWP requirement. This unit is designed and tested with R-454B and contains a dissipation system.
  • Easy Installation
  • Factory-assembled package is a compact, fully self-contained, combination gas heating/electric cooling unit that is prewired, pre-piped, and pre-charged for minimum installation expense. These units are available in a variety of standard and optional heating/ cooling size combinations with voltage options to meet residential and light commercial requirements. Units are lightweight and install easily on a rooftop or at ground level. The high tech composite base eliminates rust problems associated with ground level applications. Innovative Unit Base Design
  • On the inside a high-tech composite material will not rust and incorporates a sloped drain pan which improves drainage and helps inhibit mold, algae and bacterial growth. On the outside metal base rails provide added stability as well as easier handling and rigging. Convertible duct configuration
  • Unit is designed for use in either downflow or horizontal applications. Each unit is converted from horizontal to downflow and includes two horizontal duct covers. Downflow operation is provided in the field to allow vertical ductwork connections. The basepan seals on the bottom openings to ensure a positive seal in the vertical airflow mode. Efficient operation High-efficiency design offers SEER2 (Seasonal Energy Efficiency Ratios) of 13.4, 11.05 EER2, and AFUE (Annual Fuel Utilization Efficiency) ratings of 81.0%.
  • Energy-saving, direct spark ignition saves gas by operating only when the room thermostat calls for heating. Standard units are furnished with natural gas controls. A low-cost field installed kit for propane conversion is available for all units.
  • Low NOx units meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Durable, dependable components
  • Monoport inshot burners produce precise air-to-gas mixture, which provides for clean and efficient combustion. The large monoport on the inshot (or injection type) burners seldom, if ever, requires cleaning. All gas furnace components are accessible in one compartment.
  • Turbo-tubular heat exchangers are constructed of stainless steel for corrosion resistance and optimum heat transfer for improved efficiency. The tubular design permits hot gases to make multiple passes across the path of the supply air.
  • In addition, dimples located on the heat exchanger walls force the hot gases to stay in close contact with the walls, improving heat transfer.
  • ECM Motor is standard on all models.
  • Direct-drive PSC (Permanent Split Capacitor) condenser-fan motors are designed to help reduce energy consumption and provide for cooing operation down to 40°F (4.4°C) outdoor temperature. Motormaster® II low ambient kit is available as a field-installed accessory.
  • Thermostat controls
  • Time Guard® II anti-short cycle protection circuitry. If a non-corporate thermostat without anti-short cycle protection is used the Time Guard II field-installed anti-short cycle kit is recommended.
  • Refrigerant system is designed to provide dependability. Liquid filter driers are used to promote clean, unrestricted operation. Each unit leaves the factory with non-ozone depleting and low global warming potential R-454B refrigerant charge. Refrigerant service connections make checking operating pressures easier. Factory-installed leak detection dissipation system for added safety. High Pressure Switch provides added reliability for the compressor.
  • Item#:
    PGB460130L000B
    Manufacturer Item:
    PGB460130L000B
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • Up to 96% AFUE in upflow and horizontal positions up to 95% AFUE in downflow position
  • FixedSpeeds, Constant Torque ECM blower motor
  • Supports singlestage cooling units
  • Insulated heat exchanger compartment
  • Approved for Twinning application (0601714 through 1002120) with accessory (order separately)
  • Approved for Manufactured Housing/Mobile Home applications (0401410 through 1202422) with accessory (order separately)
  • Low NOx units are designed for California installations and meet 40 ng/J NOx emissions. Can be installed in air quality management districts with a 40 ng/J NOx emissions requirement.
  • Cabinet air leakage less than 2.0% at 1.0 in. W.C. and cabinet air leakage less than 1.4% at 0.5 in. W.C. when tested in accordance with ASHRAE standard 193

    N95ESN0801716A

  • Item#:
    N95ESN0801716A
    Manufacturer Item:
    N95ESN0801716A
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS