Sid Harvey Honeywell Protectorelay RA117A Universal Relay, 120 VAC , 75 sec Nominal
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
Item#:
R22R
Manufacturer Item:
RA117A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell Protectorelay RA116A Universal Relay, 120 VAC , 75 sec Nominal
- Interrupted ignition type
- Combine a Protectorelar unit for cycling the burner and a Pyrostat flame detector for sensing temperature changes of flue gases up to 1000 deg F
- Manual reset of safety switch required after ignition failure completely shuts off main burner
- Include manual trip safety switch to assure burner shutdown during servicing
- Mount with flange for mounting on curved or flat surfaces
- Works with 2-wire and 3-wire 24 VAC thermostat
- 2 years warranty
Sid Harvey Remanufactured R20R
Item#:
R20R
Manufacturer Item:
RA116A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184M Oil Burner Primary Control for C554A Cadmium Sulfide Cell and 24VAC Thermostat, 120/26.5 VAC , 9 amp
Sid Harvey Remanufactured R80-52R Protectorelay & Hydronic Heating Controller for Oil Hydronic System REMANUFACTURED,
Item#:
R80-52R
Manufacturer Item:
R8182E
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-40R Combination Protectorelay 5' Remote Bulb REMANUFACTURED,
Item#:
R80-40R
Manufacturer Item:
R8182H1070
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R5R Interrupted Ignition Stack Relay, 120 volt, Remanufactured
- Remanufactured with 100% pure, solid silver pyrostat contacts for longer on-the-job service life
- Backed by 2-year warranty
- All new stack relays contain brass contacts covered with a slight silver plating, it wears off as the contacts open and close, exposing the brass surface over time, the exposed surface is a poor conductor and may result in relay failure and nuisance callbacks
Item#:
R5R
Manufacturer Item:
RA817A
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-32R Control Relay Combination Control Horizontal REMANUFACTURED,
Item#:
R80-32R
Manufacturer Item:
R8182D1111
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Remanufactured R80-30R Combination Protectorelay (W/Well Adapter) REMANUFACTURED,
Item#:
R80-30R
Manufacturer Item:
R8182D1079
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey R80-58R Combination Protectorelay and Hydronic Heating Controller, 120 VAC, 4.4 amp Full Load, 26.4 amp Locked Rotor Burner at 120 VAC, 9 watt, Remanufactured
- Immersion type aquastat controller and oil burner primary control provides high limit and low limit/circulator control for oil-fired hydronic heating systems
- Use in intermittent ignition applications
- Capable of zone control with zone valves
- Circulator zone control with ZC and ZR terminals on R8182D, E, H, J
- 8-flame failure during the running cycle results in a 45 sec attempt to restart
- If unsuccessful, safety shutoff occurs, requiring manual reset before burner can be restarted
- C554A cadmium sulfide flame detector and a 24 VAC thermostat required
- Includes auxiliary ZC and ZR terminals may be used to provide circulator zone control through an R845A switching relay, horizontal case
- Maximum 250 deg F at element, 15 deg F fixed high limit differential temperature
- 45 sec safety switch timing
- 1/2"-14 NPT well spud size
- 0.2 amp anticipator setting
- 1-1/2" insulation depth,
Item#:
R80-58R
Manufacturer Item:
R8182J1059
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey 3001157 Primary Control Box for F3/F5/F10/M3/M5/M10 Riello Burner, 110 VAC at 60 Hz
Item#:
R78-10R
Manufacturer Item:
3001157
Manufacturer:
SID HARVEY REMANUFACTURED
Sid Harvey Honeywell R8184G4074 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 VAC
- Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
- Solid state flame sensing circuit
- LED on terminal strip indicates system lockout
Remote lockout indication - Enclosed safety switch with external reset butTon
- Manual trip lever opens safety switch for system maintenance
- Mounts on standard 4 x 4" junction box
- C554A cadmium sulfide flame detector and 24 VAC thermostat required
- With 30 sec safety timing, alarm outputs and manual safety switch
Sid Harvey White Rodgers Cooling Controls 668-401 Gray Metal Enclosure Kwik-Sensor CAD Cell Relay, 120 VAC, 45 sec
- Intermittent ignition kwik-sensor CAD cell relays on oil burner systems with 15, 30 or 45 sec safety timing
- Certain types have unique signal-light feature with glows whenever safety lock-out occurs
- Line voltage safety switch eliminates burner run-on in the event that the motor relay contacts weld closed
- Solid state flame detection circuitry is not affected by vibration or high or low ambient temperatures
- Recycles on momentary flame failure or power interruption
- 4 x 4 Inch junction box, 10 Inch leads mounting
- 2 wire thermostat
- 0.4 amp thermostat anticipator setting
- Safety lock-out lamp White Rodgers Cooling Controls 668-401 Gray Metal Enclosure Kwik-Sensor CAD Cell Relay, 120 VAC, 45 sec
Item#:
R79-6R
Manufacturer Item:
668-401
Manufacturer:
SID HARVEY REMANUFACTURED