|◀ 1945 - 1956 of 1984 ▶|
View:
1-1/2 thru 4 tons
  • Available for environmentally balanced R-410A systems
  • Factory installed piston metering device with Teflon ring
  • Sweat connections
  • Aluminum Tube, Aluminum Fin Evaporator
  • Primary and secondary drain fittings with brass inserts
  • Multiple electrical entry locations
  • Time delay relay (TDR)
  • Field installed heater packages from 5 kW - 30 kW available separately
  • HUD approved for manufactured housing
  • 208/230-1-60 supply voltage
  • Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard.
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation - upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
  • No Heat (Plug) Kit factory installed
  • Filter (washable) available as accessory
  • ECM 5-speed motor
  • Low voltage circuit protective fuse (3amp) inline on wire harness

    International Comfort Products FEM4X3600BL

  • Item#:
    FEM4X3600BL
    Manufacturer Item:
    FEM4X3600BL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    Fujitsu FH1817TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections

    Fujitsu FH1817TPSJSN

    Item#:
    FH1817TPSJSN
    Manufacturer Item:
    FH1817TPSJSN
    Manufacturer:
    FUJITSU(MINI-SPLITS)
    Fujitsu FH6024TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connectionsFUJITSU FH6024TPSJSN

    Fujitsu FH6024TPSJSN

    Item#:
    FH6024TPSJSN
    Manufacturer Item:
    FH6024TPSJSN
    Manufacturer:
    FUJITSU
    Fujitsu FH3617TTSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections

    Fujitsu FH3617TTSJSN

    Item#:
    FH3617TTSJSN
    Manufacturer Item:
    FH3617TTSJSN
    Manufacturer:
    FUJITSU
    Fujitsu FH3017TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
    • 42K BTU
    • 3-1/2 Ton
    • 115/1 VAC
    • 21" Wide
    • PSC Motor
    • Multi-Position,
      ,


      Fujitsu FH4221TPSASN

    Item#:
    FH4221TPSASN
    Manufacturer Item:
    FH4221TPSASN
    Manufacturer:
    FUJITSU
    Fujitsu FH4821TPSASN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
      48K BTU 4 Ton
    • 115/1 VAC
    • 21" Wide
    • PSC Motor
    • Multi-Position,
      FUJITSU FH4821TPSJSN

      Fujitsu FH4821TPSJSN

    Item#:
    FH4821TPSJSN
    Manufacturer Item:
    FH4821TPSJSN
    Manufacturer:
    FUJITSU
    Fujitsu FH3017TPSJSN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
    • 42K BTU 3-1/2 Ton
    • 208/230/1 VA
    • 21" Wide
    • PSC Motor
    • Multi-Position,




      FUJITSU FH4221TPSJSN

    Item#:
    FH4221TPSJSN
    Manufacturer Item:
    FH4221TPSJSN
    Manufacturer:
    FUJITSU
    Fujitsu FH4821TPSASN 1-Stage Standard Efficiency 95% Non-Communicating Air Handler
    The most compact unit design available, all standard heat airhandler models only 421/2 to 57"es [1079 to 1448 mm] high. Attractive pre-painted cabinet exterior. Rugged wall steel cabinet construction, designed for added strength and versatility. 1.0" foil faced insulation mechanically retained in blower compartment for excellent thermal and sound performance. Four leg blower motor mount. Blower housing with controls, motor and blower. Slide out design for service and maintenance convenience. Traditional open wire element design for heat applications. Field convertible for vertical downflow, horizontal left hand or right hand air supply. 3 combustible floor base accessories fit all model sizes when required for downflow installations on combustible floors. Indoor coil design provides low air side pressure drop, high performance and extremely compact size. Expansion valve on indoor coil provides for operation with air conditioning or heat pump using the same coil. Coils are constructed of aluminum fins bonded to internally grooved aluminum tubing. Coils are tested at the factory with an extensive refrigerant leak check.Coils have copper sweat refrigerant connections.Coils utilize chatleff metering device connections. Molded polymer corrosion resistant condensate drain pan is provided on all indoor coils. Supply duct flanges provided as standard on air handler cabinet. Provisions for field electrical, connections available from either side or top of the air handler cabinet. Connection point for high voltage wiring is inside the air handler cabinet. Low voltage connection is made on the outside of the air handler cabinet. Concentric knockouts are provided for power connection to cabinet. Installer may pull desired hole size up to 2"es [51 mm] for 11/2" [38 mm] conduit. Front refrigerant and drain connections
      48K BTU 4 Ton
    • 208/230/1 VAC
    • 21" Wide
    • Multi-Position,

      Fujitsu FH4821TTSJSN

    Item#:
    FH4821TTSJSN
    Manufacturer Item:
    FH4821TTSJSN
    Manufacturer:
    FUJITSU
    1-1/2 thru 4 tons
  • Available for environmentally balanced R-410A systems
  • Factory installed piston metering device with Teflon ring
  • Sweat connections
  • Aluminum Tube, Aluminum Fin Evaporator
  • Primary and secondary drain fittings with brass inserts
  • Multiple electrical entry locations
  • Time delay relay (TDR)
  • Field installed heater packages from 5 kW - 30 kW available separately
  • HUD approved for manufactured housing
  • 208/230-1-60 supply voltage
  • Assembled at the factory compliant with low leak requirements of less than 2% cabinet leakage rate at 0.5 inches W.C. and 1.4% cabinet leakage rate at 0.5 inches W.C. when tested in accordance with ASHRAE 193 standard.
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation - upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
  • No Heat (Plug) Kit factory installed
  • Filter (washable) available as accessory
  • ECM 5-speed motor
  • Low voltage circuit protective fuse (3amp) inline on wire harness

    INTERNATIONAL COMFORT PRODUCTS FEM4X2400CL

  • Item#:
    FEM4X2400CL
    Manufacturer Item:
    FEM4X2400CL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied

    International Comfort Products FXM4X4800AL

  • Item#:
    FXM4X4800AL
    Manufacturer Item:
    FXM4X4800AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
  • New composite base pan  dampens sound, captures louver panels, eliminates corrosion and reduces number of fasteners needed
  • Powder coat paint system  for a long lasting professional finish
  • Scroll compressor  uses 70% fewer moving parts for higher efficiency and increased reliability
  • Modern cabinet aesthetics  increased curb appeal with visually appealing design
  • Louver panels  provide ultimate coil protection, enhance cabinet strength, and increased cabinet rigidity
  • Optimized fan orifice  optimizes airflow and reduces unit sound
  • Rust resistant screws  confirmed through 1500-hour salt spray testing
  • 3"-4"-5" service valve space  provides a minimum working area of 27-square inches for easier access
  • 15" wide, industry leading corner service access  makes repairs easier and faster.
  • External gauge port access  allows easy connection of low-loss gauge ports
  • Single-row condenser coil  makes unit lighter and allows thorough coil cleaning to maintain out of the box performance
  • Fewer cabinet fasteners  allow for faster access to internal components and hassle-free panel removal
  • Service trays  hold fasteners or caps during service calls
  • QR code  provides technical information on demand for faster service calls
  • Fan motor harness with extra long wires allows unit top to be removed without disconnecting fan wire.

    Fujitsu FO4814RSJNA

  • Item#:
    FO4814RSJNA
    Manufacturer Item:
    FO4814RSJNAA
    Manufacturer:
    FUJITSU
  • 11/2 thru 5 tons
  • Available for Environmentally Sound R410A systems
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models
  • Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left standard, horizontal right with minor modification (field convertible to downflow with available accessory kit
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied
  • TXV metering device factory installed
  • ECM motor
  • Copper tube / aluminum fin coil on standard models Available with industry exclusive tin coated copper main tubing for additional corrosion protection
  • Sweat connections
  • Primary and secondary drain fittings with brass inserts
  • 3 amp automotive type fuse in wire harness
  • Multiple electrical entry locations
  • Time delay relay (TDR) programmed in motor
  • Field installed heater packages from 5 kW  30 kW available separately
  • HUD approved for manufactured housing
  • 208/230160 supply voltage
  • Units tested and certified by manufacturer to achieve a 2% or less leakage rate at 1.0 inch water column
  • 1 inch thick insulation with R value of 4.2
  • Multiposition installation  upflow or horizontal left
    standard, horizontal right with minor modification (field convertible to downflow with available accessory kit)
  • No Heat (Plug) Kit factory installed
  • Filter (washable) factory supplied

    INTERNATIONAL COMFORT PRODUCTS FXM4X4200AL

  • Item#:
    FXM4X4200AL
    Manufacturer Item:
    FXM4X4200AL
    Manufacturer:
    INTERNATIONAL COMFORT PRODUCTS
    |◀ 1945 - 1956 of 1984 ▶|
    View: