Brand Name
Voltage
Lockout Time
Ignition Type
Thermostat Voltage
Alarm Contacts
Mounting
View:
Oilco OC-10 CAD Cell Eye for Oil Primary Controls
Sid Harvey Item #:R80-100: Replaces Part #:'s : 2C860
Item#:
R80-100
Manufacturer Item:
OC-10
Manufacturer:
OILCO COMPANY
Sid Harvey 70064 Pre-Assembled Flame Detector Kit
  • Includes E-style mounting bracket, Beckett cad cell eye, 30 Inch leads
Sid Harvey Item #:R82-4: Replaces Part #:'s : 1C400C
Item#:
R82-4
Manufacturer Item:
70064
Manufacturer:
SID HARVEY INDUSTRIES INC.
The Beckett GeniSys advanced burner control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition and it has a 15 sec lockout time.
  • Thermostat and boiler control compatible
  • Customizable pretime and post time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Cad cell resistance indicator
  • Technician pump prime mode
  • Two communication ports for adding alarm contacts, programming display and future wireless communications
  • Output - 120 VAC motor, igniter, solenoid valve, 0.1 amp thermostat anticipator current
  • 5 years warranty
Sid Harvey Item #:7505A0000: Replaces Part #:'s : R7284U1004
Item#:
7505A0000
Manufacturer Item:
7505A0000
Manufacturer:
R. W. BECKETT CORP
Honeywell R7284U1004 Programmable Universal Digital Electronic Oil Primary Igniter, 120/240 VAC, 7.4/3.7 amp
  • 16-character 2-line tri-lingual display provides simple programming and diagnostics on select models
  • Enunciation of status and faults via LED or display
  • No additional tool to purchase to take advantage of all control features
  • Models with LEDs monitor igniter and cad cell
  • Models with display monitor igniter and cad cell, and alerts technician as to exact cause of lockout
  • Error history and baseline readings provide system performance and trends on models with display
  • Non volatile memory for settings and diagnostics
  • Extensive, actionable diagnostics (display models only)
  • History detailing last 10 events (display models only)
  • Continuous state and CAD cell readings (display models only)
  • Timing, safety switch settable 15, 30 or 45 sec
  • 2-line LCD display
  • Interrupted and Intermittent Ignition
  • Electrical connections: burner motor, oil valve, ignition, cad cell, limit, thermostat, alarm
  • Mounting: Junction box on main burner
Sid Harvey Item #:R7284U1004: Replaces Part #:'s : R7284U1004
Item#:
R7284U1004
Manufacturer Item:
R7284U1004
Manufacturer:
HONEYWELL
Carlin 70200S Universal Oil Primary Control for Oil and Gas, Residential and Commercial Burners, Controls and Igniters
  • Programmable, micro-processor based, universal replacement for CAD cell oil burner primary controls
  • Replaces Carlin, Beckett, Honeywell and ICM primary controls
  • On-board LCD screen no special tool needed
  • Valve delay on (0, 3, 10, 15, 30, 60, 120)
  • Trial for ignition time (15, 30, 45)
  • Motor delay off (0, 10, 15, 30, 120, 300, 900)
  • Interrupted or intermittent duty operation
  • Early spark termination timing (0, -5, -10)
  • Number of recycles (0, 3)
  • Serviceman reset protection
  • Blocked vent protection
  • Alarm contacts
  • Built-in pump prime
  • Fault history
Item#:
70200S
Manufacturer Item:
70200S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Honeywell R8184G4009 Non-Recycle Oil Burner Control with Safety Timing, 120/220/240 volt
  • Controls oil burner, oil valve (if desired) and the ignition transformer in response to a call for heat
  • Solid state flame sensing circuit
  • LED on terminal strip indicates system lockout
  • Remote lockout indication
  • Enclosed safety switch with external reset button
  • Manual trip lever opens safety switch for system maintenance
  • Mounts on standard 4 x 4 Inch junction box
  • C554A cadmium sulfide flame detector and 24 VAC thermostat required
  • With 15 sec safety timing, alarm outputs and manual safety switch
Sid Harvey Item #:R75-40: Replaces Part #:'s : R75-39R | R75-40R | ICM150
Item#:
R75-40
Manufacturer Item:
R8184G4009
Manufacturer:
HONEYWELL
Sid Harvey R82-2 Cadium Sulfide Flame Detector Kit, 60"Lead f/ A, E, J, & P Type
  • For sequencing oil burner systems use with protectorelay oil primary controls such as R4166, R4184, R8182, R8184, and R8404.
  • 2-piece model cell plug ins.
  • Includes: 4 different style mounting brackets oil line bracket, cad cell eye, 60" leads.
Sid Harvey Item #:R82-2: Replaces Part #:'s : L37-030
Item#:
R82-2
Manufacturer Item:
C554A1463
Manufacturer:
SID HARVEY INDUSTRIES INC.
Carlin 48245S Intermittent Duty Oil Burner Primary Control, 120 VAC
  • 45 sec trial for ignition
  • Red LED lockout indicator
  • Thermostat/aquastat compatible SMC (safety monitoring circuit) technology
  • 5 amp full load, 60 amp locked rotor motor load
  • 120 VAC, 60 Hz, 500 VA igniter load
Sid Harvey Item #:R75-47: Replaces Part #:'s : 7G193
Item#:
R75-47
Manufacturer Item:
48245S
Manufacturer:
CARLIN COMBUSTION TECHNOLOGY
Riello 7001029 Primary Control for 530SE/C Oil Burner
Sid Harvey Item #:620-2: Replaces Part #:'s : Q78-10 | R78-10R |
Item#:
620-2
Manufacturer Item:
7001029
Manufacturer:
RIELLO CORP OF AMERICA
The Beckett GeniSys advanced burner control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition and it has a 15 sec lockout time.
  • Thermostat and boiler control compatible
  • Customizable pretime and post time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Cad cell resistance indicator
  • Technician pump prime mode
  • Two communication ports for adding alarm contacts, programming display and future wireless communications
  • Output - 120 VAC motor, igniter, solenoid valve, 0.1 amp thermostat anticipator current
  • 5 years warranty
Sid Harvey Item #:7505B1500: Replaces Part #:'s : R7284U1004
Item#:
7505B1500
Manufacturer Item:
7505B1500U
Manufacturer:
R. W. BECKETT CORP
Item#:
20132573
Manufacturer Item:
20132573
Manufacturer:
RIELLO CORP OF AMERICA
The Beckett GeniSys advanced burner control is a 120 VAC primary safety control for residential and light commercial oil burners used in boiler, furnace and water heater applications. The GeniSys is used with a suitable cad cell flame sensor to control the oil burner motor, igniter and optional solenoid valve. It has 24 VAC thermostat terminals (if applicable) compatible with both mechanical and many power stealing thermostats. It can provide interrupted or intermittent duty ignition and it has a 15 sec lockout time.
  • Thermostat and boiler control compatible
  • Customizable pretime and post time
  • Three status lights for system monitoring and diagnostics
  • Welded relay protection with redundant motor relays
  • Limited reset and limited recycle
  • Sleek, modern design
  • Cad cell resistance indicator
  • Technician pump prime mode
  • Two communication ports for adding alarm contacts, programming display and future wireless communications
  • Output - 120 VAC motor, igniter, solenoid valve, 0.1 amp thermostat anticipator current
  • 5 years warranty
Sid Harvey Item #:7505P1515: Replaces Part #:'s : R7284U1004
Item#:
7505P1515
Manufacturer Item:
7505P1515U
Manufacturer:
R. W. BECKETT CORP
View: