These 2-position (open/close) control actuators are used with VCZ 1000, 1100, 6000 and 6100 series hydronic valves in a normal indoor environment to provide quick opening/closing to control the flow of hot and/or chilled water or glycol solution to 60% concentration. They are designed for on-off "zone" control of heating/cooling systems, or to control individual fan coil, baseboard radiator or convector applications. Depending on the model selected, the actuator can be controlled by a low or line VAC age SPST or SPDT controller, such as a room thermostat, aquastat or flow switch.
  • Double insulated actuator
  • Quick and easy replacement of moving parts
  • Actuator head installation does not require draining the system
  • Selectable/switchable electronic fail safe normally open or normally closed
  • Self alignment shaft adapter
  • SPST control signal
Sid Harvey Item #:VC8114ZZ11: Replaces Part #:'s : L40-119,

Honeywell VC8114ZZ11

,

VC8114ZZ11

Item#:
VC8114ZZ11
Manufacturer Item:
VC8114ZZ11
Manufacturer:
HONEYWELL
Item#:
VS2213
White Rodgers Cooling Controls F19-0104 2-Wire Motor Assembly for 2-Wire Zone Valves 1361-102, -103, -104
Sid Harvey Item #:B163-113: Replaces Part #:'s : 3C719,

White Rodgers Cooling Controls B163-113

Item#:
B163-113
Manufacturer Item:
F19-0104
Manufacturer:
WHITE-RODGERS DIV EMERSON
Honeywell V5013N1089 3-Way Mixing Valve 1-1/2",

V5013N1089

,

V5013N1089

Item#:
V5013N1089
Manufacturer Item:
V5013N1089
Manufacturer:
HONEYWELL
White Rodgers Cooling Controls F19-0097 3-Wire Motor Assembly for 3-Wire Zone Valves 1311-102, -103, -104
Sid Harvey Item #:B163-112: Replaces Part #:'s : 3C7193,

White Rodgers Cooling Controls B163-112

Item#:
B163-112
Manufacturer Item:
F19-0097
Manufacturer:
WHITE-RODGERS DIV EMERSON
Taco A3023522 Polyamide 4-Wire Thermal Actuator, 24 VAC Plus 20% Minus 4-wire thermal actuators mount directly onto TruFLOW Classic, TruFLOW Jr. valved, stainless-steel and EP heating manifolds. The actuators provide individual loop flow control on multi-zoned manifolds and feature an end switch for activation of a relay (pump), heat plant or other auxiliary devices. All adapter rings to mount to Uponor manifolds are included in the package.,

Wirsbo Upono A3023522

Item#:
A3023522
Manufacturer Item:
A3023522
Manufacturer:
Uponer
Taco ZA024Q4A2 Actuator Head Zone Sentry Valves 24 VAC,

Taco ZA024Q4A2

,

ZA024Q4A2

Item#:
ZA024Q4A2
Manufacturer Item:
ZA024Q4A2
Manufacturer:
TACO INC.
Caleffi Z-one Z1 Normally Closed Actuator With 18" Wire Microswitch
  • Z1 series normally closed actuator fits on Z2 and Z3 series valve bodies with the push of a butTon
  • 7/8" knockout for 1/2" conduit connector
  • With 18" wire microswitch
,

Caleffi Z111000

,

Z111000

Item#:
Z111000
Manufacturer Item:
Z111000
Manufacturer:
CALEFFI NORTH AMERICA, INC.
Honeywell 40003918-006/U Adapter Kit for V4043 or V8043 2-Way Zone Valves
Sid Harvey Item #:B163-3: Replaces Part #:'s : 40629,

HONEYWELL B163-3

,

B163-3

Item#:
B163-3
Manufacturer Item:
40003918-006
Manufacturer:
HONEYWELL
Bell & Gossett Comfort-Trol 109054 Operator and Bonnet Assembly Conversion Kit for Zone Control Valves, 3/4", Sweat
  • MCP-12 operator and bonnet assembly conversion kit converts modumate (old style) valves to comfort trol (new style) valves
  • 24 VAC , 50/60 Hz single phase operator
  • Unique torsion spring for smooth opening and closing
  • Reliable leaf-type stack switch
  • solderless electrical connection
Sid Harvey Item #:B162-3: Replaces Part #:'s : 3437,

B162-3

,

B162-3

Item#:
B162-3
Manufacturer Item:
109054
Manufacturer:
BELL & GOSSETT ITT
Bell & Gossett 189139 Bonnet and Retainer Assembly for Comfort-Trol CT-24, CTS-7524, CTF-10024 Zone Valve
  • Includes stem
Sid Harvey Item #:189139: Replaces Part #:'s : 3582,

Bell & Gossett 189139

,

189139

Item#:
189139
Manufacturer Item:
189139
Manufacturer:
BELL & GOSSETT ITT
Honeywell V8043E1004/U Brass 2-Way 2-Position Normally Closed Low VAC age Straight-Thru Zone Valve, 1/2", Sweat
  • On-off low VAC age valves consist of an actuator and valve assembly for controlling the flow of hot water
  • Manual opener for valve operation on power failure, valve returns to automatic position when power is restored
  • All models may be installed without disassembling the valve
  • Compact construction for easy installation
  • Complete powerhead may be removed or replaced without breaking plumbing line connections or draining the system
  • Actuator motor may be replaced without removing the valve body or draining the system
  • Use this valve in closed loop hydronic systems that do not contain dissolved oxygen in system water, such as fresh water from frequent source of makeup water
  • 15 sec open time
  • 18" lead electric connection
  • Spring return to close valve action
  • 50 VA pilot duty at 24 VAC , 4.4 amp running with 26.4 amp inrush at 120 VAC end switch rating
  • NO SPST auxillary end switch
  • Buna-N (NBR) rubber ball plug/ball/disc material
  • EPDM rubber packing material
  • Mounted in any position on a vertical line
,

HONEYWELL B163

,

B163

Item#:
B163
Manufacturer Item:
V8043E1004
Manufacturer:
HONEYWELL
|◀ 1 - 12 of 121 ▶|
View: